Permit Number: DP20-0236
Parcel: 13313005E

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP20-0236
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/13/2021 ELISA HAMBLIN ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: 7577 E Speedway Bl – Fire Station #16 Addition
Development Package (1st Review)
DP20-0236

TRANSMITTAL DATE: January 13, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is November 18, 2021.

1. 2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. Provide names and email addresses.

2. 2-06.4.3 – Provide case number (DP20-0236) adjacent to the title block on each sheet.

3. 2-06.4.4.A and B – Correct the project location map on sheet 1 to show the subject property approximately centered within the one square mile area to include all streets that abut the subject property (Prudence Rd and Fremming Av).

4. 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. Correct general note 3 on sheet 1 to read “Civic Use Group – Protective Service (UDC Table 4.8-2) permitted, subject to 4.9.13.F.”

5. 2-06.4.7.A.8.a and b – Correct Site Requirements on sheet 1 for RX-1 zone. Inaccurate information has been provided for R-1 zone. Minimum lot size is 36,00 sq ft and maximum lot coverage is 15%. As this site is well over the lot coverage maximum, a variance will be required. Please contact Mark.Castro@tucsonaz.gov regarding the variance process.

6. 2-06.4.7.A.8.c and d - Percentage of building, lot area, or vehicular use area expansion. If the building(s) or lot area have been previously expanded, those calculations shall be included. As the proposed expansion is part of a larger site, the calculations encompass the entire site.

7. 2-06.4.8.B – Verify all existing easements are drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. Blanket easements should be listed in the notes, together with recordation data and their proposed status. Should an easement not be in use and be proposed for vacation or have been abandoned, so indicate. However, should the easement be in conflict with any proposed building location, vacation of the easement shall occur prior to approval of plan unless written permission from easement holder(s) is provided.

8. 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.

9. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined

10. 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. Correct parking requirement and provided spaces to use the correct ratio for Protective Service (1:300 sq ft) and include all buildings and spaces on site. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled.

11. 2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long term bicycle spaces required and provided. Correct bike parking to include all buildings on site in calculation.

12. 2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown. Correct Site Requirements and Setbacks on sheet 1 which are incorrectly listed for the R-1 zone instead of the RX-1 zone. Correct all setback lines on plan. Interior perimeter yard setbacks in the RX-1 is 20 ft when adjacent to a residential zone and 0 ft when adjacent to a nonresidential zone.

13. Correct setbacks (lines and general notes) for Speedway Bl, Prudence Rd and Fremming Av. As Speedway Bl is a Major Street and Route, developing area setbacks are applied as found in UDC Article 6.4.5.C.2. Setback from all streets is 21 ft or the building wall height (whichever is greater). Speedway it is measured from the back of future curb. Prudence and Fremming is measured from outside edge of adjacent travel lane.

14. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). Provide for all buildings on the entire site.

15. 2-06.4.9.S - Show existing or proposed pedestrian circulation along abutting rights-of-way. Such sidewalks must comply with accessibility requirements for the physically disabled and the design criteria in Section 10-01.0.0, Street Technical Standards, of the Technical Standards Manual.

If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
01/14/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change DATE: January 14, 2021

Returned for Corrections / Request for Resubmittal

PERMIT/ACTIVITY: DP20-0236

DESCRIPTION: SITE - Addition to Fire Station 16, City of Tucson.

FEES DUE: $ 1,206.50
Please pay the total fees (or at a minimum, the REVIEW Fees). A payment is required before your resubmittal.

ONLINE PAYMENT
https://www.tucsonaz.gov/pdsd/fees

PLEASE READ: If information is not available or amount isn't correct, check back later after data is updated.

(Visa, MC, Discover, American Express, or pay from bank account)
1- Click on: Pay Planning & Permit Fees
2- Enter your Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave blank
4- Click the blue tab: Continue
5- Under the Pay column, check the boxes you want to pay
6- Click Continue, then enter your credit card info
7- If any issues, try using the browser Internet Explorer

RESUBMITTAL OF UPDATED/CORRECTED DOCUMENTS
Submit documents to NEW FILEDROP:
https://docs.tucsonaz.gov/Forms/tucsonpermitapp

1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Title the documents for your 2nd submittal starting with the
submittal number, for example: 2_Plan_Set

SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on View to the right of each document

FYI - For all NEW development package submittals in the future (not resubmittals) on the Filedrop page, select the box: "SITE REVIEW...".


Thank you.

City of Tucson
Attn: Sharon Beasley, Permit Specialist
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov
11/19/2020 SBEASLE1 ENGINEERING REVIEW Approved Approved by Loren Makus, 11/18/20 - see OK to Submit.
11/19/2020 SBEASLE1 START PLANS SUBMITTED Completed
12/15/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
12/18/2020 ANDREW CONNOR LANDSCAPE REVIEW Approved
12/18/2020 GDAURIA1 FIRE REVIEW Completed