Permit Number: DP20-0208
Parcel: 132041330

Address:
3225 E 36TH ST

Review Status: Completed

Review Details: REVISION - - 1ST

Permit Number - DP20-0208
Review Name: REVISION - - 1ST
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/19/2021 SBEASLE1 ZONING REVIEW Reqs Change (These are the review comments from the recent OK to Submit)

PDSD TRANSMITTAL
FROM: PDSD Zoning Review
PROJECT: Desert Metals
Development Package (Revision #1 OK to Submit), DP20-0208

TRANSMITTAL DATE: November 8, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

1. COMMENT: 2-06.4.9.R – Per TSM Section 7-01.4.1.A at least one sidewalk is required to a project from each street on which the project has frontage. The proposed asphalt pedestrian path does not meet the requirements of TSM Section 7-01.4.3.C.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
11/19/2021 SBEASLE1 ENGINEERING REVIEW Reqs Change (These are the review comments from the recent OK to Submit)

Provide a pedestrian surface that complies with TSM 7-014.3.C

Loren Makus
email: LMakus@tucsonaz.gov
12/10/2021 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: Desert Metals
ACTIVITY NO: DP20-0208
Address: 3225 E 36th st
Zoning: I-2
Existing Use: vacant, graded property

TRANSMITTAL DATE: December 10, 2021
DUE DATE: December 9, 2021
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
1. Integrate tree planting islands, diamonds, tree grates or other acceptable solution into the parking areas, placing trees along the edge of a parking area or at the ends of parking row does not meet the intent of the UDC. All spaces within 40’ of a tree is only one of the requirements. The intent is to provide as much shade on the asphalt as possible, and the requirement is 1 tree per 4 parking spaces; trees are expected to be placed within the parking area itself to mitigate the heat and glare radiated by the built environment, UDC 7.6.1.A.3. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.B.1.a., UDC Technical Standards Manual 5-01-.3.2.

2. Another tree is required for the parking area.

3. Ensure that Leucophyllum frutescens ‘Compacta’ are placed a maximum of 5’ o.c. Please add a note that plants are to provide a continuous vegetative screen.

4. Please add a detail to show depressed landscape areas or indicate with notes.

5. Provide a maintenance schedule for the landscape and irrigation for this project. UDC 2-10-4.2.A.4., please be specific.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
12/13/2021 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change Email from: COTDSDPermits
to: lisa bowers
Mon 12/13/2021 11:03 AM

REVISION REVIEW NOTICE
Returned for corrections, DP20-0208

DESCRIPTION: Site/Grading - Desert Metals, commercial storage building.

FEE BALANCE: $0 (zero)

VIEW the review comments and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on View to the right of each document

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items/documents requested by review staff


Sharon Beasley, Building Permit Specialist