| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2021 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Section Manager PROJECT: Houghton Reserve Development Package (1st Review) DP20-0179 TRANSMITTAL DATE: January 5, 2021 Zoning review conditionally approves the tentative plat subject to the changes required below. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development package to verify that those changes do not affect any zoning requirements. 1. 2-06.4.9.O – Sheet 2 under “FLD TABULATIONS” you list the required street perimeter yard setback for 5th Street as being measured “FROM FUTURE CURB” when it should be measured from the outside edge of the nearest adjacent travel lane. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 01/06/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 01/07/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | DATE: January 7, 2021 RETURNED FOR CORRECTIONS NOTICE Your Next Steps: Resubmittal of updated/corrected documents IMPORTANT - There's a new Filedrop link for your resubmittal: https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" FYI - For all NEW development package submittals in the future (not this resubmittal) on the new Filedrop page, select the box: "SITE REVIEW..." so it is routed to correct staff member for quicker processing. PERMIT/ACTIVITY: DP20-0179 DESCRIPTION: Tentative Plat/ FLD - Houghton Reserve FEE BALANCE: $0 (zero) Thank you for the payment. RESUBMITTAL OF UPDATED/CORRECTED DOCUMENTS Submit documents to NEW FILEDROP: https://docs.tucsonaz.gov/Forms/tucsonpermitapp 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Title the documents for your 3rd submittal starting with the submittal number, for example: 3_Plan_Set SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document Thank you. City of Tucson Attn: Sharon Beasley, Permit Specialist Planning and Development Services email: COTDSDPermits@TucsonAz.gov |
| 11/17/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 11/18/2020 | ALEXANDRA HINES | DESIGN PROFESSIONAL | REVIEW | Approved | Required AVP per UDC 8.7.3.M. Applicant will defer review and approval prior to building permits by submitting revision to DP20-0179. See general note 6 on sheet 2 of the plan set. |
| 12/03/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. The COT amendment to Section 714.1, IPC 2018 requires the installation of backwater valves "Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer…" Since the FFE of lots 127, 143, and 152 are all 12" above the rim elevation of the next upstream manhole, no backwater valves are required. [Initial comment: Assuming that the FFE is 0.8' higher than the pad elevation, lots 43, 44, 127, 143, and 152 are shown with backwater valves but don't require them.] 2. Lot 34 does not require a BWV. The rim elevation of MH #6 (2708.62') is more than 12" below the FFE of lot 34 (2710.87'). |
| 12/15/2020 | SBEASLE1 | PIMA COUNTY | ADDRESSING | Approved | 12/15/20 Houghton Reserve, DP20-0179, 2nd submittal, is Approved by Pima County Addressing. Thank you, Robin Freiman, Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-7570 |
| 12/16/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 12/28/2020 | SBEASLE1 | COT NON-DSD | FIRE | Reqs Change | 12/28/20 I have spoken recently to Chuck Martin from Rick Engineering concerning the Fire Code's required secondary access. In his response comments he described the location but was not clearly noted on the plans. He was going to add some notes to the plans, but I have not heard back or seen anything. The plans call-out the road to be "stabilized material, not paved as required by the Code and was only 16' wide, not the required 20'. Also, the area proposed for the access road was over a SW Gas easement which, he was to verify if he could pave over the easement. Glenn D'Auria Business Assistance Tucson Fire Department 520-837-7108 |
| 12/28/2020 | JOHN BEALL | COT NON-DSD | COMMUNITY PLANNING | Completed |