Permit Number: DP20-0179
Parcel: 13337017H

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Permit Number - DP20-0179
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2020 SBEASLE1 START PLANS SUBMITTED Completed
09/14/2020 SBEASLE1 UTILITIES SOUTHWEST GAS Passed
09/14/2020 SBEASLE1 OTHER AGENCIES U. S. POST OFFICE Passed
09/14/2020 SBEASLE1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed
09/29/2020 GDAURIA1 COT NON-DSD FIRE Reqs Change * Lots 1-38 require a second fire access per D107.1
* Show hydrants. No exterior portion of an building shall be greater than 400' from a hydrant (non-sprinklered homes) IFC 507.5.1
10/07/2020 SBEASLE1 COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this development.

Howard B. Dutt, RLA
Landscape Architect
Tucson Parks and Recreation
(520) 837-8040
10/08/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved A private improvement agreement (PIA) will be required
10/09/2020 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL



4.1 Identification and Descriptive Data



All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.



The Development Package will contain the following identification in the lower right corner of each sheet:



Any relevant case numbers for reviews or modifications that affect the site.



Provide Case # DP20-0179 on each sheet.


Provide any Rezoning condition imposed.



Verify the following has been met:



8.7.3. FLEXIBLE LOT DEVELOPMENT (FLD)



Landscaping, Screening and Wall Requirements

1. FLD projects shall comply with Section 7.6, Landscaping and Screening Standards, except as otherwise provided by this section.



Landscape plans shall incorporate water-conserving design as defined in Section 7.6.6, Use of Water, and as described in the Technical Standards Manual.



Water harvesting techniques shall be incorporated as part of the landscape design based on the Water Harvesting Guidance Manual prepared for the City of Tucson Transportation Department Stormwater Section.



Mechanical equipment, utility boxes, irrigation equipment and similar elements shall be screened from adjacent streets exterior to the project and from adjacent existing residential development. Screening shall be architecturally integrated with the overall design of the FLD.

6. If a perimeter wall is proposed along an existing public right-of-way, it shall be constructed of, or painted with, graffiti-resistant materials. The wall shall incorporate one or more of the following decorative materials:

a. Tile;

b. Stone;

c. Brick;

d. Adobe;

e. A textured material such as stucco or plaster; or,

f. Metal.



Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.



Additional comments may apply
10/12/2020 MRESS1 DESIGN PROFESSIONAL REVIEW Reqs Change Applicant is required to comply with 8.7.3.M.1, architectural Variation Plan Required and 8.7.3.M.2

In the alternative, applicant may request to defer this review until prior to the building permit approval. If applicant wishes to do this, this deferral must be indicated as a general note on the plan set.
10/12/2020 SBEASLE1 UTILITIES TUCSON ELECTRIC POWER Approved 10/09/20

Tucson Electric Power Co., (TEP) has reviewed and approves the tentative plat for Houghton Reserve submitted on September 14, 2020.

A preliminary electrical design will be prepared after receipt of information requested from Rick Engineering on September 22, 2020. A final construction drawing will prepared with an Approve Tentative Plat and approval of the preliminary design. Easements must be shown on the final plat in order for TEP to approve.

If there are any questions, please feel free to contact me at 520-401-9895.
Thank you,

Mary Burke, Senior Right of Way Agent

Tucson Electric Power Co.
Land Resources – RC 131
3950 E. Irvington Road
Tucson, AZ 85714-2114
Cell - 520-401-9895, mburke@tep.com
10/13/2020 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: Houghton Reserve
Development Package (1st Review)
DP20-0179

TRANSMITTAL DATE: October 13, 2020

DUE DATE: October 12, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is September 13, 2021.

CONTENT REQUIREMENTS

1. 2-06.4.2.C – Within the title block label this subdivision as an FLD subdivision.

2. 2-06.4.3 – Provide the development package case number, DP20-0179 , adjacent to the title block on all sheets.

2-06.4.7.A - Zoning and Land Use Notes

3. 2-06.4.7.A.6 – Demonstrate that the requirements of UDC Article 5.3.6.B are met on the plan.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. 2-06.4.9.B – Clarify where lot 227 is located.

5. 2-06.4.9.H.6 – As you are proposing a phased project demonstrate how vehicles will be prevented from access unimproved areas south of the phase line.

6. 2-06.4.9.O – Sheet 2 under “FLD TABULATIONS” you list the required street perimeter yard setback for Broadway and Houghton as being measured “FROM TRAVEL LANE” when they should be measured from back of curb or future curb.

2-06.5.0 FLEXIBLE LOT DEVELOPMENT (FLD - ADDITIONAL REQUIREMENTS)

2-06.5.3 Additional Information
The following are required in addition to the requirements of the tentative plat or site plan, whichever is applicable:

7. 2-06.5.3.C – Clarify where all of the “FUNCTIONAL OPEN SPACE “C” is located. The only “C.A. ‘C’” that could be found was on sheet 9 next to lot 146 and it is only a total of 8,919 sq. ft. and it does not appear to meet the requirements of functional open space. Clearly define all functional open space on the plan.

8. 2-06.5.3.D – Provide dimensioned building elevations of all proposed units. The elevations can be preliminary drawings. The model home construction plans will be used to determine exact setbacks and screening requirements at the time of application for building permits;

9. 2-06.5.3.G.1 – Provide three copies of the Covenants, Conditions, and Restrictions (CC&Rs) regarding the homeowner's association's responsibility for the ownership and maintenance of commonly-owned property.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
10/16/2020 SBEASLE1 PIMA COUNTY ADDRESSING Reqs Change (The ATTACHED PDF mentioned below can be viewed online: www.TucsonAz.gov/Pro. See the Documents section.)
10/16/20
Houghton Reserve, DP20-0179, 1st submittal is being Returned for Corrections by Pima County Addressing.
The attached pdf contains addressing’s corrections.
Please let me know if you have any questions.

Robin Freiman, Addressing Official

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
10/16/2020 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Reqs Change Entitlements
John Beall

Requires Change - Denied

1. At Mayor and Council Coindition 23 was added. Please add this condition to the list of rezoning conditions on the tentative plat.

Condition 23 to read: "Height in the C-1 portion of the rezoning shall be limited to 28 feet as depicted in illustration 7 witjhin the Houghton East Neighborhood Plan (HENP) Area A."
10/20/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Assuming that the FFE is 0.8' higher than the pad elevation, lots 37 and 51 appear to require backwater valves.
2. Assuming that the FFE is 0.8' higher than the pad elevation, lots 43, 44, 127, 143, and 152 are shown with backwater valves but don't require them.
11/03/2020 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. Please provide all applicable information regarding existing site conditions as per Admin Manual section 2-06.4.8.A - Provide site boundary/subdivision perimeter information, including bearing in degrees, minutes, and seconds, with basis for bearing noted, together with distances in feet, to hundredths of a foot, or other functional reference system.

Stephen Blood
stephen.blood@tucsonaz.gov
11/04/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change DATE: November 4, 2020

RETURNED FOR CORRECTIONS NOTICE
Your Next Steps: 1. Payment of review fees 2. Resubmittal of your updated/corrected documents

IMPORTANT: On the Filedrop page, select the box: "Site Review/CDRC..." when sending your next submittal.

DESCRIPTION: Tentative Plat/ FLD - Houghton Reserve

PERMIT/ACTIVITY: DP20-0179

FEES DUE: $ 16,801.82 - see image below
Please pay the total fees (or at a minimum, the REVIEW Fees). A payment is required before your next submittal.

ONLINE PAYMENTS
https://www.tucsonaz.gov/pdsd/fees

IMPORTANT: If information is not available or amount isn't correct, check back later after data transfers.

(Visa, MC, Discover, American Express or pay from checking account)
1- Click on: Pay Planning & Permit Fees
2- Enter your Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave blank
4- Click the blue tab: Continue
5- Under the Pay column, check the boxes you want to pay
6- Click Continue, then enter your credit card info
7- If any issues, try using the browser Internet Explorer

SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on View to the right of each document

YOUR NEXT STEP:
Submit documents to the Filedrop
https://www.tucsonaz.gov/pdsd-filedrop
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Title the documents for your 2nd submittal starting with the
submittal number, for example: 2_Plan_Set