Permit Number: DP20-0163
Parcel: 113071050

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Permit Number - DP20-0163
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/17/2020 SBEASLE1 START PLANS SUBMITTED Completed
08/17/2020 SBEASLE1 UTILITIES SOUTHWEST GAS Passed
08/17/2020 SBEASLE1 OTHER AGENCIES U. S. POST OFFICE Passed
08/17/2020 SBEASLE1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed
08/18/2020 GDAURIA1 COT NON-DSD FIRE Completed
08/21/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Submit an appeal to the building official stating the reason for using a common connection to the public sewer (e.g. Pima County Wastewater won't allow additional connections to the 21" sewer) and provide a proposed solution to the issue (e.g. a joint sewer use agreement). Reference: Section 701.3, IPC 2018.
09/14/2020 SBEASLE1 PIMA COUNTY ADDRESSING Reqs Change (The "ATTACHED PDF" mentioned below can be viewed online: www.TucsonAz.gov/Pro. See the Documents section.)

1620 E. Hedrick, DP20-0163, 1st submittal, is being Returned for Corrections by Pima County Addressing.
The attached pdf contains Addressing’s comments.
Please let me know if you have any questions.

Robin Freiman, Addressing Official
Pima County Development Services Department
(520) 724-7570
09/14/2020 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL



SECTION 2-10.0.0:? LANDSCAPE PLAN REQUIREMENTS



4.1???Identification and Descriptive Data



All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.



The development package will contain the following identification in the lower right corner of each sheet:



Any relevant case numbers for reviews or modifications that affect the site.



Provide Case # DP20-0163 on each sheet.



Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.





Additional comments may apply
09/15/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Reqs Change September 15, 2020
ACTIVITY NUMBER: DP20-0163
PROJECT NAME: Tentative Plat
PROJECT ADDRESS: 1620 E Hedrick Dr
PROJECT REVIEWER: Zelin Canchola Transportation and Mobility

Resubmittal Required: The following items must be revised and added to the Development plan.


1. Offsite improvements are not shown. Show new 5 feet sidewalk along frontage of Hedrick Dr

2. Close any unused driveway curb cuts. Show on plan.

3. Show elevations for new driveways and sidewalk for work in the right of way.

4. Show driveway standard detail PAG Standard detail 206.

5. Residential driveways shall be minimum 10 feet, 20 max., or 30 feet max between two properties with a 12 foot separation between driveways. Show on plan.

If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov
09/15/2020 SBEASLE1 UTILITIES TUCSON ELECTRIC POWER Reqs Change Tucson Electric Power Co., (TEP) has reviewed and approves the Tentative Plat submitted on August 17, 2020. It would be helpful if the Lot No. (14) was added to the Title Block, as shown in the Assessor Records.

Since an electrical design was not requested at this time, easements for TEP facilities will be required by separate instrument at the time of site development.

If there are any questions, please feel free to contact me at 520-401-9895.

Mary Burke, Senior Right of Way Agent
Tucson Electric Power Co.
Land Resources – RC 131
09/16/2020 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Site Section Manager

PROJECT: 1620 E Hedrick, Lots 1-3
Development Package (1st Review)
DP20-0163

TRANSMITTAL DATE: September 16, 2020

DUE DATE: September 15, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

The review comments include the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is August 16, 2021.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)
Section

2-06.1.0 GENERAL

2-06.2.0 APPLICATION SUBMITTAL REQUIREMENTS

2-06.3.0 FORMAT REQUIREMENTS

2-06.4.0 CONTENT REQUIREMENTS

2-06.5.0 FLEXIBLE LOT DEVELOPMENT (FLD) - ADDITIONAL REQUIREMENTS

2-06.1.0 GENERAL

2-06.1.1 PURPOSE
This standard has been prepared for the purpose of informing applicants of the submittal and review requirements for development package documents to assure proper and adequate information is presented in a consistent manner, thereby providing the basis for an efficient and timely review. The development package documents are prepared in support of applications for building permits and related reviews.

The information that is requested establishes the basis upon which the project will be approved and could affect what is required of the property in the future, should there be a proposal for expansion or for a different use of the property.

This standard does not waive any applicable city regulations or codes.

2-06.1.2 APPICABILITY
This standard shall be used for all site plans and tentative plats submitted to PDSD for review.

2-06.2.1 APPLICATION SUBMITTAL REQUIREMENTS
Development Package applications are available from PDSD. Completed applications and accompanying materials shall be submitted to PDSD. Incomplete or inaccurate applications will not be accepted, nor will any application in which the pre-application conference or neighborhood meeting requirements have not been met. The types of documents and the specific number of copies required of each of the documents are on the PDSD website or may be obtained from PDSD. Resubmittals of development packages require a comment response letter that details how all previous comments have been addressed. Provide the same number of copies of the comment response letter as plans provided.
The following documents and information shall be submitted upon application:

2-06.2.1 Application Form
A completed application signed by the property owner or authorized designee;

2-06.2.2 Development Package
A development package must be prepared to the format and content requirements described herein;

2-06.2.3 Related Reviews
In addition to the plan process, a project may require review for other types of plans and documents. The applications for those processes are submitted to the appropriate department for review and approval. These related reviews can be applied for so that review can occur concurrently with the development package application. However, it must be understood that, should the related application be approved subject to conditions or denied, this may affect the;

2-06.2.4 Concurrent Reviews
The development package is designed to allow for concurrent review of any site related reviews. Concurrent review means that all plans and documents needed for the review are submitted as one package. Examples of site related reviews include but are not limited to: site plans, landscape plans, NPPO plans, water harvesting plans, grading plans, SWPPP plans, floodplain use permits, and overlay reviews. Separate applications are often required for the different site related reviews even if the plans are submitted concurrently; and,

2-06.2.5 Fees
Fees in accordance with Section 4-01.0.0, Development Review Fee Schedule.

2-06.4.0 CONTENT REQUIREMENTS

1. COMMENT - 2-06.4.3 - Provide the Development Package case number, DP20-0163, adjacent to the title block on all sheets.

2. COMMENT - 2-06.4.4.B - Identify Hedrick Dr. on the location map.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

3. COMMENT - 2-06.4.7.A.4 - The "EXISTING" & "PROPOSED" use, "RESIDENTIAL" listed under General Note 3 is not correct. Residential is a Use Group, not a use. Cleary define what the existing and proposed use is on the uses provide on UDC TABLE 4.8-2: PERMITTED USES - URBAN RESIDENTIAL ZONES, R-2 zone. Also provide the applicable Use Specific Standards.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. 2-06.4.9.H.5.a - Until the use is identified, see note 3 above the vehicle parking space calculation cannot be verified.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
09/21/2020 SBEASLE1 COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this development.

Howard B. Dutt, RLA, Landscape Architect
Tucson Parks and Recreation, (520) 837-8040
09/29/2020 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. Show existing structure and proposed demolition on plans

2. A separate demolition permit will be required

3. Show water surface elevations at the proposed building corners

4. Update drainage statement to show calculations for finished floor elevations

5. Clarify if site walls will be installed and show the appropriate sized openings for flood ventilation

6. Floodplain use permit will be required for development package and will be issued at time of approval. Separate floodplain use permits and elevation certificates will also be required for each proposed building

7. Update legend to label contour lines and include WSEL for 100-yr flood

8. Show existing conditions including contour lines at least 50 feet beyond project site as per section 2-06.4.8 in the Administrative Manual

9. Add development package case number to title block

10. Show spacing of driveways, spacing between driveways, and dimensions of curb cuts

11. Show existing and proposed use of curb cut in front of lot 1

12. Clarify proposed method of elevating houses

13. Show minimum of 5 foot wide sidewalks along E Hedrick RD

Stephen Blood
stephen.blood@tucsonaz.gov
09/29/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change DATE: Sept. 29, 2020

RETURNED FOR CORRECTIONS NOTICE
Your Next Steps: Resubmittal of your updated/corrected documents

DESCRIPTION: TENTATIVE PLAT / FLOODPLAIN - 1620 E. Hedrick Drive, Lots 1-3.

PERMIT/ACTIVITY: DP20-0163
FEE BALANCE: $0 (zero) Thank you for the payment.

SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on View to the right of each document

YOUR NEXT STEP:
Submit documents to the Filedrop
https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Name the 2nd submittal documents starting with the
submittal number, for example: 2_Plan_Set

IMPORTANT:
On the Filedrop page, select the box: "Site Review/CDRC..."

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov