| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/12/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 08/12/2020 | SBEASLE1 | UTILITIES | SOUTHWEST GAS | Passed | |
| 08/12/2020 | SBEASLE1 | OTHER AGENCIES | U. S. POST OFFICE | Passed | |
| 08/12/2020 | SBEASLE1 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Passed | |
| 08/17/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 08/18/2020 | GDAURIA1 | COT NON-DSD | FIRE | Completed | |
| 09/07/2020 | SBEASLE1 | COT NON-DSD | PARKS & RECREATION | Approved | No existing or proposed Tucson Parks and Recreation facilities are affected by this development. Howard B. Dutt, RLA, Landscape Architect Tucson Parks and Recreation (520) 837-8040 |
| 09/09/2020 | SBEASLE1 | UTILITIES | TUCSON ELECTRIC POWER | Approved | Tucson Electric Power Co., (TEP) has reviewed and approves the Tentative Plat submitted on August 12, 2020. A preliminary electrical drawing for these lots is in progress. A final construction drawing will be prepared with approval of the preliminary drawing and a copy of the Approved Tentative Plat. Easements for TEP facilities will be required to be shown on the Final Plat in order for TEP to approve the plat. If there are any questions, please contact me at 520-401-9895. Thank you, Mary Burke, Senior Right of Way Agent Tucson Electric Power Co. Cell - 520-401-9895 mburke@tep.com |
| 09/09/2020 | SBEASLE1 | PIMA COUNTY | ADDRESSING | Reqs Change | (The “ATTACHED PDF” mentioned below can be viewed online: www.TucsonAz.gov/Pro. See the Documents section.) Ralph LLC, DP20-0160, 1st submittal, is being Returned for Corrections by Pima County Addressing. The attached pdf contains Addressing’s comments. Please let me know if you have any questions. Thank you, Robin Freiman, Addressing Official Pima County Development Services Department (520) 724-7570 |
| 09/09/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Reqs Change | September 9, 2020 ACTIVITY NUMBER: DP20-0160 PROJECT NAME: Tentative Plat PROJECT ADDRESS: 2102 N Ralph Av PROJECT REVIEWER: Zelin Canchola Transportation and Mobility Resubmittal Required: The following items must be revised and added to the Development plan. 1. Offsite improvements are not shown. Show new 5 feet sidewalk along frontage of Ralph Av and Senica St 2. Close any unused driveway curb cuts. Show on plan. 3. Show elevations for new driveways and sidewalk for work in the right of way. 4. Show driveway standard detail PAG Standard detail 206. If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov |
| 09/10/2020 | ANDREW CONNOR | ZONING | REVIEW | Reqs Change | ADMINISTRATIVE MANUAL The development package will contain the following identification in the lower right corner of each sheet: Any relevant case numbers for reviews or modifications that affect the site. Provide Case # DP20-0160 on each sheet. . Ensure that Zoning and Engineering comments are addressed prior to landscape section approval. Additional comments may apply |
| 09/11/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | ADMINISTRATIVE MANUAL 4.1 Identification and Descriptive Data The development package will contain the following identification in the lower right corner of each sheet: Any relevant case numbers for reviews or modifications that affect the site. Provide Case # DP20-0160 on each sheet. . Ensure that Zoning and Engineering comments are addressed prior to landscape section approval. Additional comments may apply |
| 09/25/2020 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. Add required note from Administrative Manual section 2-06.4.7.C.2 "No structure or vegetation shall be located or maintained so as to interfere with the sight visibility triangles in accordance with Section 10-01.5.0, Sight Visibility, of the Technical Standards Manual." 2. Show on plan sight visibility triangles 3. Update legend to show found and set survey monumentation 4. Need to show and label curb cuts on both E. Seneca St and N. Ralph Ave. 5. Need to show and label (2) 8'X9' Box culverts in both Seneca and Ralph 6. Provide information stated in Administrative manual 2-06.4.8.I and show on plans 7. Clarify extent of grading for this project 8. Show on plans a minimum 5' wide sidewalk along E Seneca St and N Ralph Ave Reference TSM section 10-01.4.1.A.1.a. 9. Show dimension for new proposed driveway aprons 10. Clarify on page 1 of Drainage Statement - Base Flood Elevation doesn't match between elevation certificate 11. Expand the Drainage Statement to show how adequate site drainage will be maintained and show pre vs proposed drainage patterns. Also how the BFE was determined 12. Clarify if site walls will be constructed as part of this project and if not provide a statement saying "will require a separate FUP" Stephen Blood stephen.blood@tucsonaz.gov |
| 09/25/2020 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | DATE: Sept. 25, 2020 RETURNED FOR CORRECTIONS NOTICE Your Next Steps: 1. Payment 2. Resubmittal of your updated/corrected documents DESCRIPTION: TENTATIVE PLAT/FLOODPLAIN - Ralph LLC, Lots 1-3, residential. PERMIT/ACTIVITY: DP20-0160 FEES DUE: $ 1,481.50 Please pay the total fees (or at a minimum, the REVIEW Fees). A payment is required before your next submittal. ONLINE PAYMENTS **Allow 1-2 days for correct amount to show** https://www.tucsonaz.gov/pdsd/fees (Visa, MC, Discover, American Express or pay from checking account) 1- Click on: Pay Planning & Permit Fees 2- Enter your Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave blank 4- Click the blue tab: Continue 5- Under the Pay column, check the boxes you want to pay 6- Click Continue, then enter your credit card info 7- If any issues, try using the browser Internet Explorer SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document YOUR NEXT STEP: Submit documents to the Filedrop https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Name the 2nd submittal documents starting with the submittal number, for example: 2_Plan_Set IMPORTANT: On the Filedrop page, select the box: "Site Review/CDRC..." Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov |