Review Status: Completed
Review Details: DEV PKG
Permit Number - DP20-0123
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/12/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 06/12/2020 | SBEASLE1 | ENGINEERING | REVIEW | Approved | Approved by Loren Makus on 06/11/20 (see Okay to Submit). |
| 06/12/2020 | SBEASLE1 | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields, Section Manager PROJECT: 3301 E Grant Cure Plan Development Package (1st Review), DP20-0123 TRANSMITTAL DATE: June 11, 2020 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 1. 2-06.4.9.H.a - The center bay of vehicle parking spaces needs to be moved 1.5' east to maintain a 24' wide PAAL and remove the wheel stops to allow ingress/egress from the center parking spaces. If you have any questions about this transmittal, please contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 06/12/2020 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | RETURNED FOR CORRECTIONS NOTICE Your Next Steps: 1. Payment 2. Resubmittal of documents DESCRIPTION: Site - 3301 E. Grant Rd, Grant Road Cure Plan, Phases 3 and 4 Project. PERMIT/ACTIVITY: DP20-0123 FEES DUE: $ 181.50 Please pay the total fees (or at a minimum, the REVIEW Fees). A payment is required before the next submittal. ONLINE PAYMENTS https://www.tucsonaz.gov/pdsd It may take 1-2 days for complete permit information to be available online Visa, MC, Discover, American Express or pay by checking account 1- Click blue tab: Pay Permit Fees 2- Enter your Permit Nbr, example: dp00-0006 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave blank 4- Click the blue tab: Continue 5- If any issues, try using the browser Internet Explorer SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on blue icon to the right of each document YOUR NEXT STEP: Submit documents to the Filedrop https://www.tucsonaz.gov/file-upload-pdsd For quicker processing, on the Filedrop page, select the box "Development Package or Land Division". This applies to all DP submittals, DP resubmittals, and DP revisions - and all Land Splits. (For Building Permits, continue to select "Resubmittals/Revisions...".) 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Name the 2nd submittal documents starting with the submittal number, for example: 2_Plan_Set Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/12/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |