Permit Number: DP20-0106
Parcel: 14044009M

Address:
7710 S WILMOT RD

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP20-0106
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/20/2020 SBEASLE1 START PLANS SUBMITTED Completed
05/20/2020 SBEASLE1 ENGINEERING REVIEW Approved Approved by Loren Makus on 5/19/20 (see Okay to Submit).
05/20/2020 SBEASLE1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed Review not required. This agency was notified for their information only.
05/20/2020 SBEASLE1 PIMA COUNTY ADDRESSING Passed
05/20/2020 SBEASLE1 UTILITIES SOUTHWEST GAS Passed Review not required. This agency was notified for their information only.
05/20/2020 SBEASLE1 OTHER AGENCIES U. S. POST OFFICE Passed Review not required. This agency was notified for their information only.
05/22/2020 SBEASLE1 UTILITIES TUCSON ELECTRIC POWER Approved (The TEP Facilities Map mentioned below can be viewed online: www.TucsonAz.gov/Pro. See the Documents section.)

SUBJECT: BUILDING ADDITION 7710 S. WILMOT RD.
DP20-0106
Tucson Electric Power Company (TEP) has reviewed and approved the development plan
submitted May 18 2020. It appears that there are existing TEP underground and overhead
facilities that are not depicted on plans, unable to verify if there is a conflict. See attached facilities
map.
Enclosed is a copy of a TEP facilities map showing the approximate location of the existing
facilities. Any relocation costs will be billable to the customer.
In order to apply for electric service, call the New Construction Department at (520) 918-8300.
Submit a final set of plans including approved site, electrical load, paving off-site improvements
and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should
be sent to:
Tucson Electric Power Company
Attn: Mr. Richard Harrington
New Business Project Manager
P. O. Box 711 (OH 204)
Tucson, AZ 85702
520-917-8726


Should you have any technical questions, please contact the area Designer Martin Rodriguez, at (520) 991-5495

Sincerely,
Conor Mahoney, Office Support Assistant
Design/Build
05/26/2020 GDAURIA1 COT NON-DSD FIRE Completed
05/29/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change The rim elevation of the next upstream sanitary manhole (3135-02, 2770.51') is higher than the first floor elevation (2769.10'). Add a note stating that a backwater valve will be required when future plumbing work takes place. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.
05/29/2020 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved ADOT South Central District Permits has no comments regarding this development.

Richard La Pierre, Permits Supervisor, South Central District
1221 South Second Avenue
Tucson, Arizona 85713
520.388.4234 (office), 520.307.5893 (cell)
RLaPierre@azdot.gov
06/02/2020 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL

4.1 Identification and Descriptive Data

The development package will contain the following identification in the lower right corner of each sheet:

Any relevant case numbers for reviews or modifications that affect the site.

Provide Case # D20-0106 on each sheet

Ensure that Zoning comments are addressed prior to landscape section approval.
06/09/2020 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: 7710 S Wilmot Rd - Building Addition
Development Package (1st Review)
DP20-0106

TRANSMITTAL DATE: June 9, 2020

DUE DATE: June18, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is May 19, 2021.

2-06.3.0 FORMAT REQUIREMENTS

1. 2-06.3.12 - The Drawing Index is not correct and should include all 4 sheets submitted.

CONTENT REQUIREMENTS

2. 2-06.4.2.D - The total number of pages is not correct and should be 4.

3. 2-06.4.3 - Provide the development package case number, DP20-0120 , adjacent to the title block on all sheets.

4. 2-06.4.2.C - Label the section corners on the location map.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

5. 2-06.4.7.A.4 - Clarify what a "C-STORE" is as it is not a use listed in the UDC.

6. 2-06.4.7.A.4 - The existing retail use should be listed as General Merchandise Sales, excluding Large Retail Establishment and Medical Marijuana Dispensary.

7. 2-06.4.7.A.4 - The Use Specific Standard 4.9.9.F.1 listed for both the existing and proposed Marijuana Dispensary is not correct and should be 4.9.9.E.1.

8. 2-06.4.7.A.4 - You list a proposed use of "COMMERCIAL STORAGE" as a separate use. Based on information provided on sheet 2 the storage is part of the Medical Marijuana Dispensary not a stand-alone use and should list as an expansion of the dispensary. As you are proposing an expansion to the Dispensary you need to apply for an expansion and submit as a separate submittal a Planning and Development Services Department Zoning Compliance Application Medical Marijuana Locations and all additional required documentation. This must be approved prior to approval of this development package.

2-06.4.7.A.8 - For development package documents provide:

9. 2-06.4.7.A.8.a - Under "PARKING CALCULATIONS" you list "GROSS FLOOR AREA CALCULATIONS" with the "COMMERCIAL STORAGE" listed as 641 Sq. Ft. but within the footprint on sheet 2 you list the expansion as 1,375 S.F., clarify the difference.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

10. 2-06.4.9.H.2 - The future back of curb shown on the plan is not correct. Per the Major Streets and Routes Plan, 150 FOOT RIGHT-OF-WAY figure the Pedestrian/Utility Area is 12' to the face of curb not 9' to the back of curb.

11. 2-06.4.9.H.5.a - The vehicle parking space calculation is not correct. Based on comment 8 the entire building should be based on 1 space per 300 of gfa or 28 required.

12. 2-06.4.9.H.5.d - The short- and long-term bicycle parking calculation is not correct and should be based on 8,359 sq. ft. of retail use or 2 short-term and 2 long-required.

13. 2-06.4.9.H.5.d - Based on current aerial photos the existing short-term bicycle parking is located at the southeast corner of the existing building and is being removed for the expansion. The location for the short-term bicycle parking called out under "SITE DEVELOPMENT NOTE" 2 is currently two bicycle lockers or long-term bicycle parking. If you are proposing to provide new short-term bicycle parking at this location demonstrate on the plan how the requirements of UDC Article 7.4.9.B.1.d, .e, all of 7.4.9.B.2 and 7.4.9.C.2.a, & .c.

14. 2-06.4.9.H.5.d - As you are clearly proposing to relocate the long-term bicycle provide a detail that demonstrates how the requirements of UDC Article 7.4.9.D are met or provide a copy of the approved development package/site plan that approved the long-term bicycle parking inside of the building.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
06/18/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Reqs Change June 18, 2020
ACTIVITY NUMBER: DP20-0106
PROJECT NAME: Building addition
PROJECT ADDRESS: 7710 S. Wilmot Rd
PROJECT REVIEWER: Zelin Canchola Transportation and Mobility

Resubmittal Required: The following items must be revised and added to the Development plan.

1. Show/Dimension existing and future right of way on plan according to Major Streets and Routes (MS&R)

2. Offsite improvements are not shown. As stated in the rezoning requirements:

Condition # 26 Owner developer shall design and build out the west half of the Major Streets and Routes improvements to Wilmot Road (along the Wilmot Road frontage of the site) including appropriate pavement transitions beyond the limits of the improved section, 6 foot sidewalk, and curbing along the west side of Wilmot Road, Turn lanes as required by Transportation.

3. Condition #26 A impact analysis is required, include warrant analysis for turn lanes. Include striping recommendations. The existing striping on Wilmot is not appropriate/standard for turning into proposed development.

If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov
06/19/2020 SBEASLE1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Reqs Change June 18, 2020

RE: DP20-0106 / SITE - Building addition, medical marijuana / 1st Submittal, Received May 20, 2020

Thank you for the opportunity to comment on DP20-0106, Building addition, medical marijuana; 1st Submittal, a development package application for an approximately 2.11 acre site, located southwest of the intersection of South Wilmot Road and Interstate 10. The property is zoned Commercial Zone 2 (C-2), with the proposed development being a medical marijuana dispensary.

This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace.

The Tucson Airport Authority approves the proposed project.

Although this project does not propose a change in plan designation or zoning the Tucson Airport Authority highly recommends the applicant add the following note into the general notes of the revised development plan. This project is located approximately 3 ½ miles northeast of Tucson International Airport and is within FAA traffic pattern airspace, an area which would be subject to aircraft overflight and noise due to being in close proximity to Tucson International Airport.

The proposed note would provide a means of assuring that future owners and tenants of the property are aware they are in proximity an airport and further assures the continued right of the City of Tucson, Tucson Airport Authority, and all persons lawfully utilizing the Tucson International Airport the right to utilize the airspace above or near the property. This would be accomplished through the property owner recording the Avigation Easement. The Tucson Airport Authority believes the proposed note helps to support the City of Tucson Airport Environs Overlay Zone and supports Plan Tucson – Regional and Global Positioning policy 4 (RG-4).

"That prior to the City's approval of any construction permit for a permanent building, the property owner shall record the Avigation Easement which discloses the existence, and operational characteristics of the Tucson International Airport to future owners or tenants of the property and further conveys the right to the public to lawfully use the airspace above the property. The Avigation Easement shall be recorded in a manner with the Pima County recorder which shall document it as having title liability. The content of such documents shall be according to the form and instructions provided.

The current property owner or person authorized to sign on behalf of the current property owner shall complete, sign, and record the Avigation Easement. Please record the Avigation Easement with the Pima County Recorder’s Office. Once the Avigation Easement is recorded please send a complete copy of the recorded easement document to Tucson Airport Authority by either email (send to srobidoux@flytucson.com) or to the mailing address provided below.
Scott Robidoux, Senior Airport Planner
Tucson Airport Authority
7250 South Tucson Boulevard, Suite 300
Tucson, AZ 85756”

Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811.
Respectfully,
Scott Robidoux, C.M., Senior Airport Planner
06/19/2020 SBEASLE1 COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this development.

Howard B. Dutt, RLA, Landscape Architect
Tucson Parks and Recreation
(520) 837-8040
06/22/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change RETURNED FOR CORRECTIONS NOTICE
Your Next Step: Resubmittal of documents

DESCRIPTION: SITE - Building addition, medical marijuana.
PERMIT/ACTIVITY: DP20-0106
FEE BALANCE: $0 (zero) Thank you for the payment.

SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on blue icon to the right of each document

YOUR NEXT STEP: Submit documents to the Filedrop
https://www.tucsonaz.gov/file-upload-pdsd

FOR FASTER PROCESSING, when on the Filedrop page, select the box
"Development Package or Land Division". This applies to all
DP submittals, DP resubmittals, and DP revisions - and all Land Splits.
(For Building Permits, continue to select "Resubmittals/Revisions...".)

1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Name the 2nd submittal documents starting with the
submittal number, for example: 2_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov
06/22/2020 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
06/22/2020 SBEASLE1 OUT TO CUSTOMER Completed