Permit Number: DP20-0103
Parcel: 14043011A

Address:
7211 S PARK AV

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP20-0103
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/14/2020 SBEASLE1 START PLANS SUBMITTED Completed
05/14/2020 SBEASLE1 UTILITIES SOUTHWEST GAS Passed Review not required. This agency was notified for their information only.
05/14/2020 SBEASLE1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed Review not required. This agency was notified for their information only.
05/14/2020 SBEASLE1 OTHER AGENCIES U. S. POST OFFICE Passed Review not required. This agency was notified for their information only.
05/18/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
05/19/2020 GDAURIA1 COT NON-DSD FIRE Reqs Change * Show fire access route around building to within 150' of any partion per TFC 503.1.1. Concerned aqbout sandbags noted on CI100
* Show fire access gates in fencing (20') ea. per TFC D103.5
* Fire access must comply with TFC D103.4
06/02/2020 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL

4.1 Identification and Descriptive Data

The development package will contain the following identification in the lower right corner of each sheet:

Any relevant case numbers for reviews or modifications that affect the site.

Provide Case # D20-0103 on each sheet

Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.

Remove PDSD approval stamp from cover sheet.
06/03/2020 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Site Section Manager

PROJECT: Pima Community College - Aviation Technology Center Expansion
Development Package (1st Review)
DP20-0103

TRANSMITTAL DATE: June 3, 2020

DUE DATE: June 12, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is May 13, 2021.

2-06.3.0 FORMAT REQUIREMENTS

1. 2-06.3.5 - Remove the DEVELOPMENT PACKAGE PDSD APPROVAL stamp from all sheets in the plan and reserve a 3" x 5" space in the lower right quadrant of each sheet so that an electronic stamp can be applied.

CONTENT REQUIREMENTS

2. 2-06.4.2.D - Provide the page number and the total number of pages in the package (i.e., sheet xx of xx) within the title block on all sheets.

3. 2-06.4.3 - Provide the development package case number, DP16-0 , adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

4. 2-06.4.7.A.2 - List the gross area of the site/subdivision by square footage and acreage.

5. 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses.

6. 2-06.4.7.A.6.b - Provide a general note on the cover sheet stating "THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.6 AIRPORT ENVIRONS ZONE (AEZ)".

2-06.4.7.A.8 - For development package documents provide:

7. 2-06.4.7.A.8.a - Provide the floor area for each building;2-06.4.7.A.8.c - 2-06.4.7.A.8.c - Percentage of building, lot area, or vehicular use area expansion. If the building(s) or lot area have been previously expanded, those calculations shall be included; and,

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

8. 2-06.4.8.A - Provide site boundary perimeter information, including bearing in degrees, minutes, and seconds

9. 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

10. 2-06.4.9.H.5 - Fully dimension the existing and proposed vehicle use/parking areas.

11. 2-06.4.9.H.5 - Demonstrate on the plan how the requirements for UDC Article 7.4.6.H.1 along the west side of the proposed vehicle parking.

12. 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled.

13. 2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short- and long-term bicycle spaces required and provided.

14. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s).

15. 2-06.4.9.R - Provide the width of all sidewalks and striped pedestrian refuge areas.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
06/08/2020 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP20-0103

1) Sheet 1. Add reference to DP20-0061
2) Provide waste stream calculations on plans per TSM section 8-01.8.0 showing that the existing service is sufficient for the proposed expansion. Otherwise show how the required service will be provided
3) Sheet CS002. The dimensioning of the northern parking area appears to be off. For example, the dimension of the parking area access lane should be from parking stripe to parking stripe
4) Sheet L1.0 shows a traffic island that is not shown on the grading plan. Please update as needed so that the landscape/hardscape plans matches
5) Provide a detail for all proposed accessible ramps showing that the minimum cross slope/running slope are maintained
6) Provide a detail for the accessible parking signage. Note that minimum clearance from bottom of lowest sign to finished surface is 84" if the sign is located within a pedestrian circulation area
7) Show that, with a 2.5' vehicle overhang, that the parking along the west side of the building maintains a minimum 4' pedestrian circulation path
8) The proposed western parking lot expansion. Please update the drainage report supplied for DP20-0061 to indicate the existing/proposed watershed for that area. Provide the discharge volume, CFS, for the proposed valley drain. Indicate if any erosion protection is needed at its discharge point
9) Expand the drainage report for DP20-0061 to indicate that the proposed rip-rap at the outlet point of the box culverts is of sufficient size to accommodate the proposed discharge. It is not clear if that rip rap is existing or proposed in either DP20-0061 or DP20-0103. In either case please verify if it is adequate and provide details for improvements if needed
10) Per AM section 2-06.4.8.I Floodplain information, including the location of the 100-year flood limits for all flows of 100 cfs or more with 100-year flood water surface elevations, shall be indicated. Show on plans the 100 year floodplain boundaries for all regulatory areas with in 50' of all proposed work. This appears to include the outlet point of the proposed box culverts

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
06/11/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
06/12/2020 SBEASLE1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Reqs Change June 12, 2020

RE: DP20-0103 / SITE/GRADING/SWPPP/FLOODPLAIN - Pima Community College, Aviation Technology Center Expansion / 1st Submittal, Received May 14, 2020

Thank you for the opportunity to comment on DP20-0103, Pima Community College, Aviation Technology Center Expansion, 1st Submittal, a development package application for an approximately 2.85 acre site, located northeast of the intersection of Old Nogales Highway and East Los Reales Road. The property is zoned Heavy Industrial Zone (I-2), with the proposed development being the expansion of an existing education use.

This site is within FAA traffic pattern airspace and FAA Part 77 airspace.

The Tucson Airport Authority conditionally approves the subject request contingent upon the following condition of approval, as noted below. Condition #2 shall be identified in the general notes of the revised development plan.

Condition of approval:
1. The applicant shall clarify with the TAA on if the wooden power pole, located on the western side of the project area and nearest to the active monitoring well, is being removed or relocated.

2. “The active monitoring well, located adjacent and northwest of the immediate project area, shall be provided standby electricity for the duration of the project. Under no condition may there be a loss of electricity to this active monitoring well, unless the TAA authorizes this interruption in writing.”

Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811.

Respectfully,
Scott Robidoux, C.M., Senior Airport Planner
06/12/2020 SBEASLE1 COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this developmet.

Howard B. Dutt, RLA, Landscape Architect
Tucson Parks and Recreation, (520) 837-8040
06/17/2020 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Passed
06/18/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change RETURNED FOR CORRECTIONS NOTICE
Your Next Step: Resubmittal of documents

DESCRIPTION: SITE/GRADING/SWPPP/FLOODPLAIN - Pima Community College, Aviation Technology Center Expansion.

PERMIT/ACTIVITY: DP20-0103
FEE BALANCE: $0 (zero) Thank you for the payment.

SEE REVIEW COMMENTS and your submitted documents on PRO:
www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on blue icon to the right of each document

YOUR NEXT STEP: Submit documents to the Filedrop
https://www.tucsonaz.gov/file-upload-pdsd

FOR FASTER PROCESSING, when on the Filedrop page, select the box
"Development Package or Land Division". This applies to all
DP submittals, DP resubmittals, and DP revisions - and all Land Splits.
(For Building Permits, continue to select "Resubmittals/Revisions...".)

1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Name the 2nd submittal documents starting with the
submittal number, for example: 2_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov
07/14/2020 SBEASLE1 UTILITIES TUCSON ELECTRIC POWER Approved (The TEP FACILITIES MAP mentioned below can be viewed online: www.TucsonAz.gov/Pro. See the Documents section.)

WR#6622959, July 10, 2020

SUBJECT: PIMA COMMUNITY COLLEGE AVIATION TECHNOLOGY CENTER EXPANSION, DP20-0103

Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted June 12 2020. There do not appear to be any conflicts.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Mr. Richard Harrington
New Business Project Manager
P. O. Box 711 (OH 204)
Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please contact the area Designer Martin Rodriguez, at (520) 991-5495.

Sincerely,
Conor Mahoney, Office Support Assistant
Design/Build

Final Status

Task End Date Reviewer's Name Type of Review Description
06/18/2020 SBEASLE1 OUT TO CUSTOMER Completed