Permit Number: DP20-0090
Parcel: 13018077A

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP20-0090
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/29/2020 SBEASLE1 START PLANS SUBMITTED Completed
04/29/2020 SBEASLE1 ZONING REVIEW Reqs Change (Review comments from Okay to Submit, 04.28.20)

CDRC TRANSMITTAL
TO: Development Services Department Plans Coordination Office
FROM: Steve Shields, Section Manager

PROJECT: Cordova Village Apartments - Storage Addition.
Development Package (1st Review), DP20-0090

TRANSMITTAL DATE: April 28, 2020

DUE DATE: OK to Submit.

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

CONTENT REQUIREMENTS

1. 2-06.4.3 - Provide the development package case number, DP20-0090 , adjacent to the title block on all sheets.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2. 2-06.4.9.Q - Provide the square footage and the height of the proposed structure within the foot print of the building. Also provide the height of the storage shed from the midpoint of the pitched roof to design grade. If this is greater than 12'-0" a Board of Adjustment for Variance will be required, see UDC Article 6.6.3.C.

If you have any questions about this transmittal, please contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/29/2020 SBEASLE1 PIMA COUNTY ADDRESSING Passed DP20-0090, 2020 S. Columbus Blvd.

The above referenced project submitted to the City of Tucson will not require review by Pima County Addressing.
Please note that the building numbers on the site plan do not match the official building numbers with Pima County Addressing per addressing plan EB 05095 dated 7/13/2010.

The proposed storage building does require a new building number.

Please let me know to whom I can issue the invoice for the $86 addressing fee.

Thank you
Nicholas Jordan, Addressing Specialist
Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-9623
Nicholas.Jordan@Pima.gov
05/04/2020 GDAURIA1 FIRE REVIEW Completed
05/05/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change RETURNED FOR CORRECTIONS NOTICE
Your Next Step: 1. Payment 2. Resubmittal of documents

DESCRIPTION: SITE - Cordova Vlg. Apts, new storage shed.

PERMIT/ACTIVITY: DP20-0090
FEES DUE: $ 16.50 (technology & archive fee)

ONLIINE PAYMENT
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. NOTE: It may take 1-2 days for complete information to be viewable
2. Visa, MC, Discover, American Express or pay by checking account
3. Not case-sensitive but a hyphen is needed, for example: dp19-2000
4. Enter Permit Nbr
5. Business/Individual Name: Leave blank
6. Click the Continue tab
7. If any issues, try using the browser Internet Explorer

SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Reviews section, click on Review Details
- Documents section, click on blue icon to the right of each document

YOUR NEXT STEPS: Submit to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Name the 2nd submittal documents starting with the submittal number, for example: 2_Plan_Set

NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue (the physical office) is closed to the public until further notice. Our staff is working remotely. All communications are by telephone or email.

CONTACT US Monday-Friday, 8:00 am to 12:00 noon
https://www.tucsonaz.gov/pdsd/virtual-service-counter
To request information or an over-the-counter review,
sign in to the Virtual Service Counter and we will give you a call.

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
05/05/2020 SBEASLE1 OUT TO CUSTOMER Completed