Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP20-0087
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/21/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 04/21/2020 | SBEASLE1 | LANDSCAPE | REVIEW | Approved | Approved per Steve Shields, 4/20/20 (see LHN). |
| 04/21/2020 | SBEASLE1 | ZONING | REVIEW | Reqs Change | From 4/20/20 Okay to Submit: CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields, Section Manager PROJECT: El Rio Golf Course - Solar Canopies Development Package (1st Review) DP20-0087 TRANSMITTAL DATE: April 20, 2020 DUE DATE: OK to Submit COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). CONTENT REQUIREMENTS 1. 2-06.4.3 - Provide the development package case number, DP20-0087 , adjacent to the title block on all sheets. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 2. 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: right-of-way width, dimensioned width of paving, curbs, and sidewalks. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 3. 2-06.4.9.J - If street dedication is not required or proposed and the project site is adjacent to a Major Street or Route, draw the Major Street right-of-way lines for those streets. (Add the MS&R future sidewalk, right-of-way lines, sight visibility triangles, etc.) As Speedway is not currently at full show the future right-of-way line and future curb location. 4. 2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown. The street perimeter yard setback is not shown correctly. As there is future right-of-way the street perimeter yard is measured from the back of future curb. 5. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). Per UDC Article 6.6.3.C Accessory structures shall not exceed 12 feet in height, unless attached to a principal structure. It appears that the proposed structure is exceeding the 12' in height, provide a height dimension from the midpoint of the pitched roof, see UDC Article 6.4.4. If you have any questions about this transmittal, please contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 05/04/2020 | GDAURIA1 | FIRE | REVIEW | Completed | |
| 05/05/2020 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | RETURNED FOR CORRECTIONS NOTICE Your Next Step: 1. Payment 2. Resubmittal of documents DESCRIPTION: SITE - El Rio Golf Course, City of Tucson. PV shade canopies, solar. PERMIT/ACTIVITY: DP20-0087 FEES DUE: $ 346.50 Please pay the total fees (or Review Fees at a minimum). A payment is required before the next submittal. ONLIINE PAYMENT https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records 1. NOTE: It may take 1-2 days for complete information to be viewable 2. Visa, MC, Discover, American Express or pay by checking account 3. Not case-sensitive but a hyphen is needed, for example: dp19-2000 4. Enter Permit Nbr 5. Business/Individual Name: Leave blank 6. Click the Continue tab 7. If any issues, try using the browser Internet Explorer SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Reviews section, click on Review Details - Documents section, click on blue icon to the right of each document YOUR NEXT STEPS: Submit to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Name the 2nd submittal documents starting with the submittal number, for example: 2_Plan_Set CONTACT US Monday-Friday, 8:00 am to 12:00 noon https://www.tucsonaz.gov/pdsd/virtual-service-counter To request information or an over-the-counter review, sign in to the Virtual Service Counter and we will give you a call. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/05/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |