Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP20-0081
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/01/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 10/12/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 10/13/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Section Manager PROJECT: McDonald’s – Campbell & Benson Hwy Development Package (2nd Review) DP20-0081 TRANSMITTAL DATE: October 13, 2020 DUE DATE: October 13, 2020 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is April 15, 2021. 1. 2-06.4.7.A.6.a – Revise General Note 11 to include the UDC Article number for the MS&R 5.4 and include Gateway Corridor Zone (GCZ) 5.5. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 2. This comment was not fully addressed, provide the recordation information on the plan. 2-06.4.8.B – If applicable show all existing easements on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 3. This comment was not addressed. 2-06.4.9.H.5.a – The wheel stop location dimension shown on detail 4 sheet SD# is not correct, see UDC Article 7.4.6.H.3. 4. This comment was not addressed. 2-06.4.9.L – It appears that there are several proposed easements shown on the plan, provide the recordation information on the plans. 5. This comment was not addressed. 2-06.4.9.L – The proposed “24’ ACCESS LEASE” will need to be recorded and the recordation information provided on the plan. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 10/13/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | A private improvement agreement will be required for improvements in the right of way. Zelin Canchola Transportation and Mobility Engineering |
| 10/20/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 10/30/2020 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. See previous comment 3 - Sheet L10. Update the Water Budget chart so that the volumes of the water harvesting areas take into account how the basins will be constructed which will include basin side slopes. Doesn't look like this was addressed. Please update water budget chart and/or include typical cross section of water harvesting landscape area to show side slopes and volume calculations. 2. See previous comment 2 - Provide spot grades in all depressed landscaped areas. Spot grades to take into account the depth of ground cover proposed. Looks like a few spot elevations were added but labeled as concrete elevations in the landscape area. Please correct the labeling and even add a few more. 3. Update legend on cover sheet to include all symbology used in drawings (eg. FG, G, TW, etc.) Stephen Blood stephen.blood@tucsonaz.gov |
| 11/02/2020 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | DATE: November 2, 2020 RETURNED FOR CORRECTIONS NOTICE Your Next Steps: Resubmittal of your updated/corrected documents IMPORTANT: On the Filedrop page, select the box: "Site Review/CDRC..." when sending your next submittal. DESCRIPTION: SITE/GRADING/SWPPP - McDonalds, Benson Hwy/Campbell Ave, new restaurant. PERMIT/ACTIVITY: DP20-0081 FEE BALANCE: $0 (zero) Thank you for the payment. SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document YOUR NEXT STEP: Submit documents to the Filedrop https://www.tucsonaz.gov/pdsd-filedrop 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Title the documents for your 3rd submittal starting with the submittal number, for example: 3_Plan_Set IMPORTANT: On the Filedrop page, select the box: "Site Review/CDRC..." when sending your next submittal. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov |