Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP20-0069
Parcel: 10821328B

Address:
1880 E RIVER RD

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP20-0069
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/08/2020 SBEASLE1 START PLANS SUBMITTED Completed
04/27/2020 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL

SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS

4.1 Identification and Descriptive Data

A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

The development package will contain the following identification in the lower right corner of each sheet:

Any relevant case numbers for reviews or modifications that affect the site.

Provide Case # DP20-0069 on each sheet. Including NPP Application for Exception.

Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.


Additional comments may apply
04/27/2020 NICHOLAS ROSS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Nick Ross
Lead Planner

PROJECT:
Development Package (1st Review)
DP20-0069

TRANSMITTAL DATE: April 27, 2020
DUE DATE: April 29, 2020


COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is April 27, 2021.

2-06.3.4 - A title block shall be provided in the lower right quadrant of each sheet.

COMMENT: Please add “DP20-0069” to the title block.

2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications. The basis for this requirement is that some zoning requirements on a project are based on the zoning classification of adjacent property. Also, in some instances, each zone has to be taken into consideration on property that is split by two or more zoning classifications, as each may have different requirements.

COMMENT: In addition to C-1, part of the site is zoned R-3 and MH-1. Show all zoning classifications on site and for all adjacent parcels.

2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

COMMENT: The overhang for all shade structures for parking spaces must stop 1’ before the end of the parking spaces for vehicle clearance in the PAALs. Verify any new shade structure complies with this standard.

2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual.

COMMENT: Show ADA ramp details for new parking areas (south of Building 1840 and east of Building 1860)

If you have any questions about this transmittal, please contact me at Nicholas.Ross@tucsonaz.gov or (520) 837-4029.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/28/2020 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP20-0069

1) Sheet A.1. Reference to Sheet A1.3 is not correct. A1.3 appears to be occurring where sheet A1.2 is being referenced. Please update sheet references as needed
2) For the proposed parking spaces which would be removing a dumpster and enclosure. Provide on plans waste stream calculations per City of Tucson (COT) Technical Standards Manual (TSM) section 8-01.8.0. Show that existing service is satisfactory give that proposed removal. If additional service is required show how it will be provided. Show on plans location and volume of existing service
3) Show cross slope and running slope for all proposed new ADA parking spaces. Also provide dimensions and slopes for new ADA pedestrian paths

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
04/29/2020 GDAURIA1 FIRE REVIEW Completed * Verify that covered parking does not infring in on the required fire access (min. 20' width w/18' radius turns.
04/30/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change RETURNED FOR CORRECTIONS NOTICE
Your Next Step: Resubmittal of documents

DESCRIPTION: SITE - Cambric Corp. Center. Increase parking.
PERMIT/ACTIVITY: DP20-0069
FEE BALANCE: $0 (zero)

SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Reviews section, click on Review Details
- Documents section, click on blue icon to the right of each document

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Name your 2nd submittal documents to start with the submittal number, for example: 2_Plan_Set

NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue (the physical office) is closed to the public until further notice. In the meantime, our staff is working remotely from home. All communications are by telephone or email.

CONTACT US Monday-Friday, 8:00 am to 12:00 noon
https://www.tucsonaz.gov/pdsd/virtual-service-counter
To request information or an "over-the-counter" review,
sign in to the Virtual Service Counter and we will give you a call.

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
04/30/2020 SBEASLE1 OUT TO CUSTOMER Completed