Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP20-0065
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/23/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 04/13/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 04/21/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Section Manager PROJECT: Work Shop & Porch Addition for Robert Brookbank Development Package (1st Review) D209-0065 TRANSMITTAL DATE: April 5, 2016 DUE DATE: April 21, 2016 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is March 22, 2021. CONTENT REQUIREMENTS 1. 2-06.4.3 - Provide the development package case number, DP20-0065, adjacent to the title block on all sheets. 2. 2-06.4.4.C - The Section corners labeled as "26" are incorrect and should 36. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 3. 2-06.4.7.A.4 - General Note 3 references "NON-RESIDENTIAL USE GROUP" this use group is not a use group within the UDC and should read "RESIDENTIAL USE GROUP" 2-06.4.7.A.8 - For development package documents provide: 4. 2-06.4.7.A.8.c - Provide a building expansion calculation on the plan. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 5. 2-06.4.8.A - Provide site boundary perimeter information, including bearing in degrees, minutes, and seconds together with distances in feet, to hundredths of a foot 6. 2-06.4.8.C - The following information regarding existing public right-of-way adjacent to the site shall be provided: the dimensioned width of paving, curbs, curb cuts, and sidewalks. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 7. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. 8. 2-06.4.9.O - The street perimeter yard dimension from the proposed workshop to Yavapai Rd is not correct. As this site boarders on Stone which is a MS&R route designated on the City of Tucson Major Streets and Routes Plan as streets that this site boarders on shall use the developing area setbacks as listed in UDC Table 6.4.5.C-1. The street perimeter yard for Yavapai is measured from the nearest edge of travel lane. 9. 2-06.4.9.R - Per TSM Section 7-01.3.3 a sidewalk is required from the proposed workshop to all existing structures on site and to both streets. 10. There are two (2) General Notes 4. The first talks about "EXPANSION ON LOT SHALL NOT BE BEDROOM OR ACCESSORY STRUCTURE", remove the reference to "ACCESSORY STRUCTURE" from the note as the work shop is an accessory structure. 11. There are two (2) "STG" shown to be relocated. Clearly show where they are going to be relocated to and provide all applicable perimeter yard setback dimension. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 04/21/2020 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 04/22/2020 | SSHIELD1 | LANDSCAPE | REVIEW | Approved | |
| 04/27/2020 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP20-0065 1) Provide on plans waste stream calculations per City of Tucson (COT) Technical Standards Manual (TSM) section 8-01.8.0. Show that existing service is satisfactory for proposed expansion. If additional service is required show how it will be provided. Show on plans location and volume of existing service 2) Provide a pedestrian circulation connection from the proposed building to both Stone Av and Yavapai Rd. Reference TSM section 7-01.4.1.D 3) Sheet 2, Adjust the call out "PROPOSED NEW PORCH" which is pointed to "(E) MAIN UNIT 2 1 BEDROOM" so that it points towards the hatched area which represents the new porch John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 04/28/2020 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | RETURNED FOR CORRECTIONS NOTICE Your Next Step: Resubmittal of documents DESCRIPTION: SITE - Work Shop and Porch Addition for Robert Brookbank. PERMIT: DP20-0065 FEE BALANCE: $0 (zero) SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Reviews section, click on Review Details - Documents section, click on blue icon to the right of each document YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Name your 2nd submittal documents to start with the submittal number, for example: 2_Plan_Set NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue (the physical office) is closed to the public until further notice. In the meantime, our staff is working remotely from home. All communications are by telephone or email. CONTACT US INFO: To speak with a Permit Counter staff member on the telephone, please sign into the Virtual Zoning Counter: https://www.tucsonaz.gov/pdsd/virtual-service-counter The queue is open from 8:00 am -12:00 noon, Monday-Friday. TIP: It’s better to sign in closer to 8 than 12 noon. This is similar to the City’s in-person counter but instead over the phone. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/28/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |