Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - OK TO SUBMIT
Permit Number - DP20-0057
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/16/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 03/17/2020 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Section Manager PROJECT: Walmart - 1650 W Valencia - Online Pickup Development Package (1st Review) DP20-0057 TRANSMITTAL DATE: March 17, 2020 OK to Submit COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package 1. A small, project-location map shall be provided in the upper right corner of the cover sheet. This map shall cover approximately one square mile, be drawn at a minimum scale of three inch equals one mile, and provide the following information; a. Show the subject property approximately centered within the one square mile area. Identify major streets within the square mile area and all streets that abut the subject property. Section, township, and range, north arrow, and the scale will be labeled. 2. The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. 3. Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. 4. Sheets 1 & 2 need to be combined as one PDS file. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 03/17/2020 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 03/20/2020 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | PLAN DENIED FOR REVIEW NOTICE / Changes are required NOTE: Please follow the steps below to resubmit your documents for review. Permit/Activity Number: DP20-0057 Project Description: SITE - Walmart (Valencia), parking stalls, canopy, paint, sign. To view the "Dev Pkg - Okay to Submit" comments by Reviewers online: 1. www.tucsonaz.gov/pro 2. Home page, left side - Activity Search 3. Enter the Activity Number 4. Under "Permits" heading, click on blue tab (Permit/Activity Number) 5. In "Reviews" section, click on (blue) Review Details (If information isn't shown yet, check back later as data transfers to PRO periodically.) After corrections are made, name your documents again as a first submittal (the number one leads the title), for example: 1_Application. Upload all documents to the City of Tucson's Filedrop page: www.tucsonaz.gov/file-upload-pdsd Thank you. Sharon City of Tucson Planning and Development Services Attn: Sharon Beasley, Permit Specialist 201 N. Stone Avenue, 3rd Floor Tucson, AZ 85701 email: COTDSDPermits@TucsonAz.gov NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue is closed to the public until further notice due to the corona virus. In the meantime, our office is still fully staffed but all communications will be via telephone or email. City of Tucson updates: https://www.tucsonaz.gov/manager/covid-19-updates |