Permit Number: DP20-0055
Parcel: 111051740

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP20-0055
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/13/2020 SBEASLE1 START PLANS SUBMITTED Completed
04/06/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
04/09/2020 SBEASLE1 PIMA COUNTY ADDRESSING Reqs Change (The attached PDF mentioned below can be viewed online: www.TucsonAz.gov/Pro. See the Documents section.)

DP20-0055 Solmod residential development is being Returned for Corrections by Pima County Addressing.

The attached pdf contains Addressing’s comments.

Please let me know if you have any questions.
Thank you,
Robin Freiman, Addressing Official
Pima County Development Services Department
(520) 724-7570
04/13/2020 NICHOLAS ROSS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Nick Ross
Lead Planner

PROJECT:
Development Package (1st Review)
DP20-0055

TRANSMITTAL DATE: April 13, 2020
DUE DATE: April 13, 2020


COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is April 13, 2021.


2-06.4.2 - The title block shall include the following information and be provided on each sheet:

COMMENT: Include Activity Number “DP20-0055” on all sheets

2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.

COMMENT: Total ROW is accurate, however per Paving Plan I-63-016 the ½ ROS should equal 30ft. Revise drawing to reflect accurate dimensions.

2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

COMMENT: Parking space dimensions do not meet minimum requirements. The backup spur located just north of Building 1 must be dimensioned. Additionally, provide typical floor plan to verify parking calculations are accurate.

2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long term bicycle spaces required and provided.

COMMENT: Floor plan required to verify bicycle parking count.

2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown.

COMMENT: Provide setback measurements for the sheds located along the east side of the property. Heights and dimensions for the sheds will be required to verify setbacks are being met.

2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s).

COMMENT: See previous comment.

2-06.4.9.S - Show existing or proposed pedestrian circulation along abutting rights-of-way. Such sidewalks must comply with accessibility requirements for the physically disabled and the design criteria in Section 10-01.0.0, Street Technical Standards, of the Technical Standards Manual.

COMMENT: A pedestrian path connecting from Presidio Rd to each unit is required.

2-06.4.9.T - Show refuse collection areas, including locations of dumpsters, screening location and materials, and vehicle maneuverability, fully dimensioned, and access route. If dumpster service is not proposed, indicate type of service. For specific information on refuse collection, refer to Section 8-01.0.0, Solid Waste and Recycle Disposal, Collection, and Storage, of the Technical Standards Manual. Refuse collection on all projects shall be designed based on that section, even if collection is to be contracted to a private firm.

COMMENT: Indicate how/where refuse collection is occurring on the site.



If you have any questions about this transmittal, please contact me at Nicholas.Ross@tucsonaz.gov or (520) 837-4029.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/16/2020 GDAURIA1 FIRE REVIEW Reqs Change * Fire Access Roads (driveway) must extend to within 150' ofall potions of all structures.
04/21/2020 LOREN MAKUS ENGINEERING REVIEW Reqs Change DP20-0055
1. Show there is enough space to service the required 10 APCs along the street frontage. See TSM 8-09.0 Figure 8.
2. Check the symbols used for notes and ensure callouts are correct. For example, the numeral 8 inside a hexagon is used in two locations for two different meanings. Check all callouts and details for consistency.
3. Check spelling throughout the notes on the plans.
4. Keynote 9 indicates the driveway is a modified version of PAG SD 209. Provide a detail of the modifications and reference the detail in the note.
5. Keynote 14 says to see hardscape plan. Indicate sheet number or use consistent titles in sheet index.
6. Clarify on sheet 2 (Site Plan) which existing features are to be replaced or modified and which are to remain. For example, Keynote 1 indicates "existing verticle curb" at the location of the proposed driveway.
7. The parking area cross section shows 2.5 feet from the end of the parking space to the property line. Show the perimeter wall in the detail and provide sufficient spacing between the parking curb and the wall.
8. Show barriers along vehicle use areas to prevent vehicles from leaving the paved areas and driving into landscape areas.
9. Clearly show adequate vertical separation between pedestrian and vehicle use areas where they are adjacent. (TSM 7-01.4.2.A)
10. Show drainage patterns, including roof drainage throughout the site. Show how water harvesting will be maximized.
11. Ensure roof drainage is not directed over sidewalks.
Loren Makus
loren.makus@tucsonaz.gov
04/22/2020 PETER MCLAUGHLIN LANDSCAPE REVIEW Reqs Change Correct spelling of site address in the title block in the lower right hand corner of all sheets to read "Presidio Rd" rather than "Presidion Rd".

In Landscape note #7 revise to read "within" 30 days instead of "with" 30 days.

Peter McLaughlin
peter.mclaughlin@tucsonaz.gov
837-4898
04/23/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change RETURNED FOR CORRECTIONS NOTICE
Your Next Steps: 1. Payment 2. Resubmittal with a Comment Response Letter

DESCRIPTION: SITE - Solmod, residential development.

PERMIT: DP20-0055

FEES DUE: $ 1,206.50
Note: A payment is required before we can accept your resubmittal.

PAYMENT OPTIONS Please pay the total fees (or Review Fees at a minimum)
1. Online Payment

Online Payment
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. NOTE: It may take 1-2 days for complete permit information to be available online
2. Visa, MC, Discover, American Express or pay by checking account
3. Not case-sensitive but a hyphen is needed, for example: dp19-2000
4. Enter your Permit Nbr
5. Business/Individual Name: Leave blank
6. Click the blue Continue tab
7. If any issues, try using the browser Internet Explorer

SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Reviews section, click on Review Details
- Documents section, click on blue icon to the right of each document

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Name your 2nd submittal documents to start with the submittal number, for example: 2_Plan_Set

NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue (the physical office) is closed to the public until further notice. In the meantime, our staff is working remotely from home. All communications are by telephone or email.

CONTACT US: To speak with a staff member on the telephone, please sign into the Virtual Zoning Counter:
https://www.tucsonaz.gov/pdsd/virtual-service-counter
The queue is open from 8:00 am -12:00 noon, Monday-Friday.
It’s better to sign in closer to 8 than 12 noon.
This is similar to the City’s in-person counter.
The difference is after you sign up, we will give you a call.

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
04/23/2020 SBEASLE1 OUT TO CUSTOMER Completed