Permit Number: DP20-0049
Parcel: 132165930

Address:
1800 E BENSON HY

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP20-0049
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/09/2020 SBEASLE1 START PLANS SUBMITTED Completed
03/09/2020 SBEASLE1 ZONING REVIEW Reqs Change CDRC TRANSMITTAL
TO: Development Services Department, Plans Coordination Office
FROM: Steve Shields, Section Manager
PROJECT: PEPP - Solar Canopies & ADA Changes
Development Package (1st Review), DP20-0049
TRANSMITTAL DATE: March 6, 2020
DUE DATE: OK to Submit

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

CONTENT REQUIREMENTS
1. 2-06.4.3 - Provide the development package case number, DP20-0049 , adjacent to the title block on all sheets.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2. 2-06.4.9.H.5 - Per UDC Article 7.4.6.F.2.a.(1) Access lanes and PAALs must be setback at least one foot from (1) An open structure, such as a carport or covered pedestrian access path as measured from the closest part of the structure or roof overhang

3. 2-06.4.9.H.5.a - The wheel stop shown on detail "B", sheet A-2.1 is not in the correct location, see UDC Article 7.4.6.H.3.

4. 2-06.4.9.H.5.a - As a vehicle parking space is being removed to accomadate the new accessible vehicle parking spaces provide a vehicle parking calculation on the plan. This calculation should include the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled.

5. 2-06.4.9.H.5.a - Provide a note on the plan stating that all accessible route slopes are to comply with ICC A117.1, Section 403.3; 5% maximum running slopes and 2% maximum cross slopes.

6. 2-06.4.9.O - The street perimeter yard setback dimensions shown are not shown correctly. Per UDC Article 11.4.6 Definition of Established Area Setback, this site would be considered Developing Area for the purpose of determining street perimeter yard setback requirements Per UDC Article 6.4.5.C.2 and Table 6.4.5.C-1 the minimum street perimeter yard is 21" or the height, greater of the two, measured from the back of future curb. The future curb is located 9' from the existing street property line.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/14/2020 MARTIN BROWN FIRE REVIEW Approved
04/15/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change RETURNED FOR CORRECTIONS NOTICE
Your Next Steps: 1. Payment 2. Resubmittal with a Comment Response Letter

DESCRIPTION: SITE - PEPP Benson Hwy, solar PV canopy structure.
PERMIT: DP20-0049

FEES DUE: $ 264.00
Note: A payment is required before we can accept your resubmittal.

PAYMENT OPTIONS Please pay the total fees (or Review Fees at a minimum)
1. Online Payment

Online Payment
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. NOTE: It may take 1-2 days for complete permit information to be available online
2. Visa, MC, Discover, American Express or pay by checking account
3. Not case-sensitive but a hyphen is needed, for example: dp19-2000
4. Enter your Permit Nbr
5. Business/Individual Name: Leave blank
6. Click the blue Continue tab
7. If any issues, try using the browser Internet Explorer

SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back in a few days as we have recently implemented new computer software.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Reviews section, click on Review Details
- Documents section, click on blue icon to the right of each document

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff

- Name your 2nd submittal documents to start with the submittal number, for example: 2_Plan_Set

To speak with a staff member on the telephone, please sign into the Virtual Zoning Counter: https://www.tucsonaz.gov/pdsd/virtual-walk-thru. The queue is open from 8:00 am -12:00 noon, Monday-Friday. This is similar to the City’s in-person counter. The difference is after you sign up, we will give you a call.

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov

NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue (the physical office) is closed to the public until further notice. In the meantime, our staff is working remotely from home. All communications are by telephone or email.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/15/2020 SBEASLE1 OUT TO CUSTOMER Completed