03/05/2020 SBEASLE1 START PLANS SUBMITTED Completed
03/06/2020 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: PEPP - Solar Canopies & ADA Changes
Development Package (1st Review)
DP20-0049

TRANSMITTAL DATE: March 6, 2020

DUE DATE: OK to Submit

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


CONTENT REQUIREMENTS

1. 2-06.4.3 - Provide the development package case number, DP20-0049 , adjacent to the title block on all sheets.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2. 2-06.4.9.H.5 - Per UDC Article 7.4.6.F.2.a.(1) Access lanes and PAALs must be setback at least one foot from (1) An open structure, such as a carport or covered pedestrian access path as measured from the closest part of the structure or roof overhang

3. 2-06.4.9.H.5.a - The wheel stop shown on detail "B", sheet A-2.1 is not in the correct location, see UDC Article 7.4.6.H.3.

4. 2-06.4.9.H.5.a - As a vehicle parking space is being removed to accomadate the new accessible vehicle parking spaces provide a vehicle parking calculation on the plan. This calculation should include the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled.

5. 2-06.4.9.H.5.a - Provide a note on the plan stating that all accessible route slopes are to comply with ICC A117.1, Section 403.3; 5% maximum running slopes and 2% maximum cross slopes.

6. 2-06.4.9.O - The street perimeter yard setback dimensions shown are not shown correctly. Per UDC Article 11.4.6 Definition of Established Area Setback, this site would be considered Developing Area for the purpose of determining street perimeter yard setback requirements Per UDC Article 6.4.5.C.2 and Table 6.4.5.C-1 the minimum street perimeter yard is 21" or the height, greater of the two, measured from the back of future curb. The future curb is located 9' from the existing street property line.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
03/06/2020 SSHIELD1 ENGINEERING REVIEW Passed
03/09/2020 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Passed