Permit Number: DP20-0040
Parcel: 136383140

Review Status: Completed

Review Details: DEV PKG - OK TO SUBMIT

Permit Number - DP20-0040
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/26/2020 SBEASLE1 START PLANS SUBMITTED Completed
02/26/2020 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Passed This project does not require review by Pima County Addressing.
Thank you
Nicholas Jordan, Addressing Specialist
Pima County Development Services Department
201 N Stone AV – 1st Floor, Tucson, AZ 85701
(520) 724-9623
02/28/2020 LOREN MAKUS ENGINEERING REVIEW Passed DP not required. Should be submitted as Residential Building Permit
03/02/2020 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change
03/02/2020 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: 7301 E Marigold Cir.
DP20-0040
Development Package

TRANSMITTAL DATE: March 2, 2020

The development package has been reviewed by the Zoning Review Section for minimal compliance with the Administrative Manual Section 2-06. It has been determined that the submitted plans do not provide sufficient information to complete a plan review. The following items need to be addressed prior to re-submittal.

1. This project does not require a development package (DP) submittal. Withdraw the DP and resubmit the plans along with a Permit Application. The correct application can be found at https://www.tucsonaz.gov/files/pdsd/forms/PERMIT_APPLICATION_1-16-19_fillable.pdf

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The required residential plot plan must meet the requirements as shown on the residential plot plan requirements available at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements.

2. The plot plan shall be drawn at an engineering scale, i.e.l 1" = 10'-0".
3. Show the square footage of each of the following;
a. Lot
b. Existing dwelling
c. Garage addition
d. All accessory structures on site
e. Total gross floor area
4. Provide a lot coverage calculation.
5. Show the locations of utility lines for water; sewer; electric and gas.
6. Show ht e street perimeter yard setback on the plan. Show a dimension from the center line of the street to the curb and from the curb to the street property line.
7. If applicable show all easements of record for this property.
8. Indicate the zoning of the property and of the surrounding propertities.
9. Provide a legal description on the plan.
10. Per Unified Development Code (UDC) Table 6.3-2.A the minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line. Based on a twelve (12') foot high wall the required perimeter yard setback to the north and west property line is 8'-9" a Design Development Option will need to be applied for and approved prior to Zoning approving this plan.
11. The property dimensions shown on the plan are not correct.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956