Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP20-0027
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/04/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 02/25/2020 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 02/25/2020 | DJELLEN1 | ZONING | REVIEW | Reqs Change | FROM: David Jellen PDSD Zoning Review Section PROJECT: DP20-0027 El Rio Community Health Center (1st Review) 839 W Congress St TRANSMITTAL DATE: February 25, 2020 DUE DATE: February 27, 2020 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: Provide the Development Package activity number, DP20-0027, adjacent to the title block on each sheet. Additionally, provide as General Notes the Board of Adjustment conditions approved for the site. 02. COMMENT: Provide a lot coverage calculation for the site. Show that the R-2 portion of the site does not exceed the originally approved 92% maximum lot coverage, per Board of Adjustment Variance C10-13-04. 03. COMMENT: Add St Mary's Rd, Church Ave, Cushing St, and Main Ave to the location map. If you have any questions about this transmittal, Contact David Jellen at (520) 837-4082 or by email David.Jellen@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
| 03/02/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 03/03/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | ADMINISTRATIVE MANUAL 4.1 Identification and Descriptive Data The development package will contain the following identification in the lower right corner of each sheet: Any relevant case numbers for reviews or modifications that affect the site. Provide Case # DP20-0027 on each sheet. Indicate graphically, where possible, compliance with conditions of rezoning(s). The following information must be provided on the landscape plans. A. Planting Plan Both the proper and common name of each type of plant material. Location, size, and name of existing vegetation to remain in place; Material and areas of inert ground cover. Provide planting plan. Ensure that Zoning, Engineering and Design Professional comments are addressed prior to landscape section approval. Additional comments may apply. |
| 03/11/2020 | PCAMARE1 | ENGINEERING | REVIEW | Reqs Change | TO: Development Services Department Plans Coordination Office FROM: Paul Camarena PDSD Engineering Review Section PROJECT: EL RIO COMMUNITY HEALTH CENTER Development Package (1st Review) 837 W CONGRESS ST DP20-0027 TRANSMITTAL DATE: March 11, 2020 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Engineering Review Section comments were addressed. 1.The parking lot addition is going to built where a water harvesting basin is located. On DP12-0234 it calls out the area as a water harvesting basin “B”. 2.Demonstrate how the volume produced by basin “B” will captured by the rest of the site. If you have any questions about this transmittal, Contact Paul Camarena at Paul.Camarena@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 03/12/2020 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/12/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |