Permit Number: DP20-0022
Parcel: 129063980

Address:
2201 E 21ST ST

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP20-0022
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/24/2020 SBEASLE1 START PLANS SUBMITTED Completed
01/24/2020 SBEASLE1 ZONING REVIEW Reqs Change (From Okay to Submit, 01.24.2020)

CDRC TRANSMITTAL

TO: Development Services Department, Plans Coordination Office
FROM: Steve Shields, Section Manager
PROJECT: Cornerstone Electric LLC
Development Package (1st Review), DP20-0022
TRANSMITTAL DATE: January 24, 2020
DUE DATE: OK to Submit

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is January 23, 2021.

2-06.3.0 FORMAT REQUIREMENTS

1. 2-06.3.2 - All mapped data shall be drawn at an engineering scale having no more than 50 feet to the inch.

2. 2-06.3.7 - A small, project-location map shall be provided in the upper right corner of the cover sheet, See requirements below, 2-06.4.4

3. 2-06.3.12 - An index of sheets in the development package shall be provided on the first sheet.

CONTENT REQUIREMENTS

4. 2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, shall be provided on the right half of the cover sheet.

5. 2-06.4.2.D - The page number and total number of sheets does not appear to be correct. The total number of sheets is "6" but there is only one sheet.

6. 2-06.4.3 - Provide the development package case number, DP20-0022 , adjacent to the title block on all sheets.

7. 2-06.4.4 - The project-location map to be located on the first sheet of the development package in the upper right corner, shall cover approximately one square mile, be drawn at a minimum scale of three inch equals one mile, and provide the following information.

8. 2-06.4.4.A - Show the subject property approximately centered within the one square mile area;

9. 2-06.4.4.B - Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property; and,

10. 2-06.4.4.C - Section, township, and range; section corners; north arrow; and the scale will be labeled.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

11. 2-06.4.7.A.1 - The zoning listed for this site is not correct and should be listed as C-1.

12. 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. This note should state "EXISTING/PROPOSED USE CONSTUCTION SERVICES PER LEGAL NONCONFORMING LETTER DATED JANUARY 19M, 2011. PER THIS LETTER THE 1976 SITE PLAN SHOWS PARKING FOR ONE CAR IN THE FRONT YARD AND FOUR CARS IN THE REAR YARD WITH ACCESS FROM PLUMBER AVENUE ONLY; THE PARKING SPACES AND ACCESS MUST BE MAINTAINED PE THE SITE PLAN". Provide a copy of the 1976 site plan with your next submittal and ensure that the proposed work meetings the conditions listed.

13. 2-06.4.7.A.4 - Clarify what the new structures are going to be used for.

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

14. 2-06.4.8.A - Provide site boundary perimeter information, including bearing in degrees, minutes, and seconds.

15. 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

16. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined.

17. 2-06.4.9.H.2 - Show future and existing sight visibility triangles. On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section.

18. 2-06.4.9.H.4 - Indicate if existing streets are public or private; provide street names, widths, curbs, sidewalks, and utility locations, all fully dimensioned.

19. 2-06.4.9.O - Provide a front street perimeter yard dimension from the proposed southern structure to the street property line. Per UDC 6.4.5.C.1 the required setback is 20 feet or one and one-half the height of the proposed wall (H), measured from the street property line.

20. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). This includes the proposed solar structures.

21. 2-06.4.9.S - Show existing pedestrian circulation along abutting rights-of-way.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
01/24/2020 SBEASLE1 ZONING HC REVIEW Reqs Change See Zoning review comments, if applicable.
01/24/2020 SBEASLE1 ENGINEERING REVIEW Passed Passed by Loren Makus, 01.22.2020 (See Okay to Submit).
02/25/2020 MARTIN BROWN FIRE REVIEW Approved
03/03/2020 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL

4.1 Identification and Descriptive Data

The development package will contain the following identification in the lower right corner of each sheet:

Any relevant case numbers for reviews or modifications that affect the site.

Provide Case # DP20-0022 on each sheet.

Ensure that Zoning comments are addressed prior to landscape section approval.
03/03/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
Your Next Steps: 1. Payment 2. Resubmittal with a Comment Response Letter

DESCRIPTION: SITE - Cornerstone Electric Solar.

PERMIT: DP20-0022
For faster service, please enter this number in the Filedrop's "Project Description" field and on correspondence

FEES DUE: $ 429.00
Note: A payment is required before we can accept your resubmittal.
PAYMENT OPTIONS Please pay the total fees (or Review Fees at a minimum)
1. Online Payment
2. In person at the City Permit Counter (Mon-Fri, 8:00 AM to 2:00 PM)
3. By mail - a check payable to the City of Tucson (address is below), include the Activity Number

Online Payment
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. NOTE: It may take 1-2 days for complete permit information to be available online
2. Visa, MC, Discover, American Express or pay by checking account
3. Not case-sensitive but a hyphen is needed, for example: dp19-2000
4. Enter your Permit Nbr
5. Business/Individual Name: Leave blank
6. Click the blue Continue tab
7. If any issues, try using the browser Internet Explorer

SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on Review Details

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
- Filedrop: In the Project Description field, enter the Activity/Permit Number
- Name your 2nd submittal documents to start with the submittal number, for example: 2_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 2nd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
03/03/2020 SBEASLE1 OUT TO CUSTOMER Completed