Permit Number: DP20-0017
Parcel: 107040150

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP20-0017
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/04/2020 SBEASLE1 START PLANS SUBMITTED Completed
02/11/2020 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
PDSD Zoning Review Section

PROJECT: Dragoon Business Center Expansion - Wholesale / Commercial Storage Uses
Development Package (1st Review) - 2574 N. Dragoon Street
DP20-0017 - I-1 Zoning / (Less than 25% expansion)

TRANSMITTAL DATE: February 11, 2020
DUE DATE: February 25, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is January 15, 2020.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

1. COMMENT: 2-06.3.12 - Clarify if a landscape plan was to be included in the DP package. It is not clear if the registrant Danny Quihuis is providing landscape or building services on this plan.

2. COMMENT: 2-06.4.1 - List on the cover sheet the telephone number for registrant Danny Quihuis.

3. COMMENT: 2-06.4.2.C - It appears that a portion of the new building will straddle the lot line between lots 7 and 8. Prior to approval of the DP, a Pima County Tax Parcel combo must be processed and approved.

4. COMMENT: 2-06.4.2.D - If landscape plan sheets are required for the expansion area, assure that the sheet index is revised and the sheet numbers in the title blocks are adjusted accordingly.

5. COMMENT: 2-06.4.3 - Provide the development package case number, DP20-0017, adjacent to the title block on each sheet.

6. COMMENT: 2-06.4.4.B - Label the following street names in the location map; Miracle Mile and Romero Road.

7. COMMENT: 2-06.4.7.A.4 - Revise the use note as follows; Storage Land Use Group - Commercial Storage Subject to 4.9.10.A & 4.9.13.Q / Wholesaling Land Use Group - List the specific use and applicable Use specific standards.


8. COMMENT: 2-06.4.7.A.8.a - List under general note 5 the proposed building square footage of the new building and new outdoor storage area.

9. COMMENT: 2-06.4.7.A.8.b - Include the outdoor storage area expansion in general note 22.

10. COMMENT: 2-06.4.8.A - If a Pima County Tax Parcel combo is not proposed, an option to record a
"Covenant Regarding Development and use of Real Property". Contact Steve Shields if the owner wishes to execute this document instead of the Pima County Tax Parcel combo.

11. COMMENT: 2-06.4.8.B - Draw and label the 15-foot private drainage easement that applies to lots 6 - 8 as recorded per M/P 49/84.

12. COMMENT: 2-06.4.8.C - Label the existing Dragoon Street curb to property line dimension.

13. COMMENT: 2-06.4.9.H.5.a - It is suggested that one of the existing ADA spaces be relocated closer to the new building entrance.

14. COMMENT: 2-06.4.9.H.5.d - Demonstrate the location and type of long term bicycle parking facilities. If the facilities are proposed within the building indicate the locations on the site plan sheet and provide a fully dimensioned detail for the facilities.

15. COMMENT: 2-06.4.9.Q - Provide the use proposed within the footprint of the building(s).

16. COMMENT: 2-06.4.9.R - On sheet 3, Keynote 4 has been labeled on the existing storage area. Keynote 4 is also used for identifying a sidewalk on other locations of the site plan. Clarify the use and revise keynote 4 to the correct keynote for this area.

17. COMMENT: 2-06.4.9.T - The refuse collection area and type could not be verified on the site plan. Draw and label the location and type.


***For additional information on the any standard presented in this memo, please refer to the City of Tucson "Unified Development Code" - Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations


If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
02/25/2020 MARTIN BROWN FIRE REVIEW Approved
02/27/2020 LSHAMIS1 LANDSCAPE REVIEW Reqs Change Landscape plans required.
02/28/2020 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. Show the extent of the existing drainage easement and electric easements as shown on the plat.
2. Show the existing drainage connection to the Santa Cruz River.
03/02/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Revise the site drawing to include the point of connection to the public sewer. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2018.
2. The rim elevation of the next upstream sanitary manhole (2505.02', #6700-05) is less than 12" below the first floor elevation (2505.5'). Provide a note on the plans requiring the installation of a backwater valve when future plumbing activities take place. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.
03/03/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
Your Next Steps: 1. Payment 2. Resubmittal with a Comment Response Letter

DESCRIPTION: SITE/GRADING/SWPPP - Spectra Dragoon - business center expansion.

PERMIT: DP20-0017
For faster service, please enter this number in the Filedrop's "Project Description" field and on correspondence.

FEES DUE: $ 2,639.00
Note: A payment is required before we can accept your resubmittal.
PAYMENT OPTIONS Please pay the total fees (or Review Fees at a minimum)
1. Online Payment
2. In person at the City Permit Counter (Mon-Fri, 8:00 AM to 2:00 PM)
3. By mail - a check payable to the City of Tucson (address is below), include the Activity Number

Online Payment
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. NOTE: It may take 1-2 days for complete permit information to be available online
2. Visa, MC, Discover, American Express or pay by checking account
3. Not case-sensitive but a hyphen is needed, for example: dp19-2000
4. Enter your Permit Nbr
5. Business/Individual Name: Leave blank
6. Click the blue Continue tab
7. If any issues, try using the browser Internet Explorer

SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on Review Details

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
- Filedrop: In the Project Description field, enter the Activity/Permit Number
- Name your 2nd submittal documents to start with the submittal number, for example: 2_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 2nd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
03/03/2020 SBEASLE1 OUT TO CUSTOMER Completed