Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP19-0317
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/22/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 04/19/2021 | AWARNER1 | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Anne Warner, RLA Planner, PDSD Zoning Review Section PROJECT: Placita Del Rio - 902 W IRVINGTON RD Development Package (2nd Review) DP19-0317 TRANSMITTAL DATE: April 19, 2021 DUE DATE: April 16, 2018 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year expiration date is March 22, 2022. 2-06.3.0 FORMAT REQUIREMENTS 1. COMMENT: 2-06.4.2.D – The landscape sheets have been removed, the pages are mis-numbered, sheets should be number xx out of 15, not 19. 2-06.4.0 DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) 2. COMMENT: 2-06.4.9.H.5.a - The whole site should reflect adherence to the UDC, please provide a detail for a typical van accessible space. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. 3. COMMENT: 2-06.4.9.H.5.d – The whole site should reflect adherence to the UDC, please show location of existing bicycle parking. 4. COMMENT: 2-06.4.9.W - Provide a general note stating that all signs will be approved on a separate permit. 5. Key Note 3 is missing from sheet 3. If you have any questions about this transmittal, please contact Anne Warner, RLA at anne.warner@tucsonaz.gov or call 520.837.4969 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 04/20/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 04/20/2021 | SSHIELD1 | LANDSCAPE | REVIEW | Approved | |
| 04/21/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: J Morse Wed 4/21/2021 11:05 AM Returned for Corrections PERMIT/ACTIVITY: DP19-0317 DESCRIPTION: SITE/GRADING/SWPPP - Placita Del Rio, Lots 1,6,7. 820 W IRVINGTON RD RESUBMITTAL - FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp (Select "Existing Application", then the permit number) 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Title your 3rd submittal documents according to this example: 3_Comment Response Letter, 01.01.21 SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document Sharon Beasley Permit Specialist City of Tucson, Planning and Development Services email: COTDSDPermits@TucsonAz.gov (Disregard any automatic reply you might receive) |