Permit Number: DP19-0315
Parcel: 117072090

Address:
702 S 6TH AV

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0315
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/22/2020 SBEASLE1 START PLANS SUBMITTED Completed
05/29/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
06/03/2020 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change Applicant is requesting variances to allow for a reduction in the number of required vehicle parking spaces and to modify and/or delete the required street landscape borders.

The development package will contain the following identification in the lower right corner of each sheet:

Any relevant case numbers for reviews or modifications that affect the site.

Provide Case #'s C10-20-03 & T20SA00161 on each sheet.

Add date of approval and any conditions imposed.

Obtain permission in writing from TDOT for use of ROW

Landscape section cannot approve plans until BOA variance is completed and approval granted.
06/10/2020 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: Primavera 17TH Street - Commercial Use Group / Administrative Office
Development Package (1st Review) - 702 S. 6th Avenue
DP19-0315 - C-3 Zoning

TRANSMITTAL DATE: June 10, 2020
DUE DATE: June 22, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is December 26, 2020.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

2-06.3.0 FORMAT REQUIREMENTS

CONTENT REQUIREMENTS

Previous comment 6. This comment was not addressed. COMMENT: 2-06.4.8.A - This project is to be developed over two parcels. Prior to approval of the DP a Pima County Tax Parcel Combo must be processed.

Previous comment 8. The Board of Adjustment must be approved prior to approval of this DP. If approved provide the Board of Adjustment case number adjacent to the title block on all sheets. Also provide a general note stating the Board of Adjustment case number, date of approval, what was modified and if applicable any conditions of approval. COMMENT: 2-06.4.9.H.5.a - A total of 34 parking spaces are required for this development. Seven (7) spaces have been provided on site. A board of adjustment variance to reduce the number of spaces by 27 will be required.

Previous comment 9. This comment was not addressed. Your response to comment 9 states that "Added offsite parking not of DCS (Downtown Core Subdistrict) to general note 18. The note you added references UDC Article 5.12.10.C, 5.12.10.C only apples if you are using the IID and your response to comment 5 state 'This is not an IID proposal" Are you using the IID or not? COMMENT: 2-06.4.9.H.5.b - Provide the information if off-site parking is applicable for this development.

Previous comment 12. This comment was not addressed. The PDMR/TSMR request does not address elimination of the required sidewalk. Per TSM Section 7-01.4.1.B A sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located (See Figure 1); Provide the required sidewalk. The TSMR will need to be submitted and approved. If approved provide the TSMR case number adjacent to the title block on all sheets. Also provide a general note stating the TSMR case number, date of approval, what was modified and if applicable any conditions of approval. COMMENT: 2-06.4.9.R - A minimum 4-foot wide sidewalk is required between the south side of the 1-story building and the PAAL (T.S. 7.4.1.B). In addition the sidewalk must be extended out the Stone Avenue right of way and connect to the existing sidewalk.

***For additional information on the any standard presented in this memo, please refer to the City of Tucson "Unified Development Code" - Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
06/15/2020 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. Once the TSMR and variance are approved, add the required informantion to the plan.
06/17/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change RETURNED FOR CORRECTIONS NOTICE
Your Next Step: Resubmittal of documents

DESCRIPTION: SITE/GRADING - Primavera 17th Street.
PERMIT/ACTIVITY: DP19-0315
PROJECT MANAGER: Mallory.Ress@Tucsonaz.gov
FEE BALANCE: $0 (zero) Thank you for the payment.

SEE REVIEW COMMENTS and your submitted documents on PRO:
www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on blue icon to the right of each document

YOUR NEXT STEP: Submit documents to the Filedrop
https://www.tucsonaz.gov/file-upload-pdsd

FOR FASTER PROCESSING, when on the Filedrop page, select the box
"Development Package or Land Division". This applies to all
DP submittals, DP resubmittals, and DP revisions - and all Land Splits.
(For Building Permits, continue to select "Resubmittals/Revisions...".)

1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Name the 4th submittal documents starting with the
submittal number, for example: 4_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
06/17/2020 SBEASLE1 OUT TO CUSTOMER Completed