Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - DP19-0289
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/09/2019 | ALEXANDRA HINES | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Passed | |
| 12/11/2019 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | TO: Development Services Department Plans Coordination Office FROM: David Rivera PDSD Zoning Review Section PROJECT: Stockpile - Grading plan for TAA Aerospace Parkway Development Package (1st Review) 9385 S Country Club Road DP19-0289 - I-2 Zoning TRANSMITTAL DATE: December 11, 2019 DUE DATE: December 27, 2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is November 21, 2020. 1. COMMENT: 2-06.4.1 - List on the cover sheet the owner's contact name and email address. 2. COMMENT: 2-06.4.3 - Provide the development package case number, DP19-0289, adjacent to the title block on each sheet. List the administrative address next to the title block of all plan sheets. 3. COMMENT: Zoning will approve the grading plan once it is approved by the PDSD Engineering and Landscape reviewers. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson "Unified Development Code" - Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Corrected DP package as noted above for zoning |
| 12/24/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | ADMINISTRATIVE MANUAL SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS 4.1 Identification and Descriptive Data All improvements and site information, such as adjacent rights-of-way and property lines, shown on the NPP/ Landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. The development package will contain the following identification in the lower right corner of each sheet: Any relevant case numbers for reviews or modifications that affect the site. Provide Case # DP19-0289 on each sheet. Ensure that Zoning and Engineering comments are addressed prior to landscape section approval. Additional comments may apply. |
| 12/31/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP19-0289 1) Include all standard applicable notes found in the COT Administrative Manual (AM) section 2-06, including but not limited to the hold harmless note in AM 2-06.4.7 and Drainage will remain in its natural state note 2) There is an "UNKOWN WASH" which appears to be impacted by the fill area. It flows in a northwesterly direction. Please clarify if this is a regulatory flow (100 cfs) or greater. If the wash is regulatory show the 100 year floodplain boundary 3) There are two areas that appear to not maintain existing drainage patterns. As shown on sheet 3, the flow arrow at the south-east corner, and the flow arrow at the northeast corner, will be blocked by the proposed fill pad 4) Sheet 1. Please adjust general note 22 to reflect the correct COT standards 5) Sheet 1. Remove general note 29. Reseeding bonds are no longer being supported 6) This project will require a pre-construction meeting prior to issuance of the development package permit. Project will require EOR certification prior to final inspection John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 12/31/2019 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE NOTE: A resubmittal with a Comment Response Letter is required. Permit/Activity Number: DP19-0289 Include this number on all future correspondence. Project Description: GRADING/SWPPP - TAA 550 acres, Tucson Airport Authority, aerospace parkway. Onsite mass grading and stockpile. Project Managers (City): John.VanWinkle@TucsonAz.gov and Loren.Makus@TucsonAz.gov Fee Balance: $0 (zero) View the documents and the reviewer's comments online: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Documents section, click on blue icon to the right of each document - Reviews section, click on "Review Details" Submit the following items to the Filedrop. In the Project Description field, enter the Activity Number. PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff 4) Name your 2nd submittal documents accordingly, for example: 2_Plan_Set Thank you. Sharon Beasley, Permit Specialist NOTE: All City of Tucson offices will be closed on Wednesday, January 1 (except for emergency services). Planning & Development Services will be open normal business hours on Thursday and Friday: https://www.tucsonaz.gov/pdsd/contact-us-hours-service. City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, 2nd Floor Tucson, AZ 85701 email: COTDSDPermits@TucsonAz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/31/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |