Permit Number: DP19-0286
Parcel: 11942006F

Review Status: Completed

Review Details: DEV PKG - OK TO SUBMIT

Permit Number - DP19-0286
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/18/2019 SBEASLE1 START PLANS SUBMITTED Completed
11/18/2019 SBEASLE1 WWM REVIEW Passed
11/19/2019 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Passed This project does not require review by Pima County Addressing.
Thank you
Nicholas Jordan, Addressing Specialist
Pima County Development Services Department
201 N Stone AV – 1st Floor, Tucson, AZ 85701, (520) 724-9623
11/19/2019 JOHN VAN WINKLE ENGINEERING REVIEW Denied DP19-0286

The submitted plans do not address the following

1) The west branch of the Santa Cruz River is a WASH ordinance wash and is subject to chapter 29 of the Tucson City Code
2) Arial imagery from 1998 to 2018, particularly starting around 2010 shows a significant amount of fill being place on site which was done without permit. This fill has mostly occurred within the boundaries of the 100 year floodplain

Any plans submitted to develop this site will need to address the historic grading that has occurred and how it has impacted the existing floodplain boundary and any associated impacts which would otherwise be documented through chapter 29 of the Tucson City Code

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
11/21/2019 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change PLAN DENIED FOR REVIEW NOTICE / Changes are needed
Please follow the steps below to resubmit your documents.

NOTE:
All City of Tucson offices, except for emergency services, will be closed next Thursday, Nov. 28.
We will be open on Friday, Nov. 29, but with limited service to the public.

Permit/Activity Number: DP19-0286
Include this number on all future correspondence and uploads.

Project Description: SITE - Rincon Country RV West Resort, RV storage and parking.

To view the "Okay to Submit" comments by Reviewers:
1. www.tucsonaz.gov/pro
2. Home page, left side - Activity Search
3. Enter the Activity Number
4. Under "Permits" heading, click on blue tab (Permit/Activity Number)
5. Under "Reviews" heading, click on Review Details
6. Check the Status column
(If information isn't shown yet, check back later as data transfers to PRO periodically.)

After corrections are made, name your documents again as a first submittal (the number “1” leads the title), for example: 1_Application.

Before uploading to the Filedrop, enter the Permit Number in the Project Description field.
PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd

Thank you.
Sharon

City of Tucson
Planning and Development Services
Attn: Sharon Beasley, Permit Specialist
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
11/21/2019 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: Rincon Country West - RV Parking
DP19-0286
Development Package

TRANSMITTAL DATE: November 21, 2019

The development package has been reviewed by the Zoning Review Section for minimal compliance with the Administrative Manual Section 2-06 and although the provided plan meets the minimal requirements it cannot be accepted at this time because there is currently an open development package, DP18-0211, for this site. Either this needs to be submitted as a revision to DP18-0211 or DP18-0211 needs to be withdrawn.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956