Permit Number: DP19-0274
Parcel: 11007412C

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0274
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/04/2020 SBEASLE1 START PLANS SUBMITTED Completed
02/11/2020 MALLORY RESS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Nicholas Martell
PDSD Zoning Review Section

PROJECT: SEAVER FRANKS, NEW OFFICE BLDG
Development Package (2nd Review) 2562 N ALVERNON WY
DP19-0274 - O-3 Zoning

TRANSMITTAL DATE: February 11, 2020
DUE DATE: February 12, 2020

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is November 05, 2020.

1. COMMENT: 2-06.4.9.O - The DDO Application (DDO-20-01) has been received and initialized. The development package will not be approved until the DDO is approved.

***For additional information on the any standard presented in this memo, please refer to the City of Tucson "Unified Development Code" - Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations


If you have any questions about this transmittal, Contact Nicholas Martell at (520) 837-6933 or by email Nicholas.Martell@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov
02/11/2020 MROSS2 COT NON-DSD FIRE Approved
02/12/2020 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL

SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS

4.1 Identification and Descriptive Data

All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

The Development Package will contain the following identification in the lower right corner of each sheet:

Any relevant modifications that affect the site.

Include DDO approval date and conditions imposed.

The development package will not be approved until the DDO is approved.
02/12/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Measuring along the developed pipe length means that the vertical portions of the pipe must be included in the maximum distance between cleanouts. The 100-foot section of building sewer shown on the private utility plan has a developed length of 104.9-feet. Revise the cleanout locations to limit the distance between cleanouts to a maximum of 100-feet of developed length. [Initial comment: The maximum distance between cleanouts shall be 100-feet, measured along the developed pipe length. Reference: Section 708.1.1, IPC 2018.]
02/14/2020 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP19-0274

1) Previous comment 6. A bleed pipe is only needed if the retention basin has excessive infiltration times. In this case it is shown that the basin has an adequate infiltration rate so as to not have standing water. The bleed pipe is not needed. Please update the detail to either remove the bleed pipe or show a cap at the uphill side that can be used for maintenance purposes if needed. Please reference the last paragraph in section 2.2 of the Stormwater Detention/Retention Manual
2) In lieu of a separate grade control marker please indicate if the top of the cutoff wall located in detail M on sheet 5 is an acceptable location for reference when a basin inspection occurs. It is understood that this has not previously been enforced however in an effort to better inspect and maintain the approximately 1400 basins within the City Limits it is asked that that this requirement be accounted for
3) Engineering can conduct an expedited electronic review once the above comments are addressed. Please email to schedule

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
02/18/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
Your Next Steps: Resubmittal with a Comment Response Letter

DESCRIPTION: SITE/GRADING - Seaver Franks, new office building.

PERMIT: DP19-0274
For faster service, please include this number in the Filedrop's "Project Description" field.

FEE BALANCE: $0 (zero)
SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on Review Details

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
- Filedrop: In the Project Description field, enter the Activity/Permit Number
- Name your 3rd submittal documents to start with the submittal number, for example: 3_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 2nd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
02/18/2020 SBEASLE1 OUT TO CUSTOMER Completed