Permit Number: DP19-0269
Parcel: 112045000

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP19-0269
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/06/2019 SBEASLE1 START PLANS SUBMITTED Completed
11/06/2019 SBEASLE1 ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: La Madera Park - Shade Structure
Development Package (1st Review)
DP19-0269

TRANSMITTAL DATE: November 5, 2019

DUE DATE: OK to Submit

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is November 4, 2020.

CONTENT REQUIREMENTS

1. 2-06.4.2.D - In the lower right corner of the title block provide the page number and the total number of pages in the package (i.e., sheet xx of xx).

2. 2-06.4.3 - Provide the development package case number, DP19-0269 , adjacent to the title block on all sheets.

3. 2-06.4.2.C - For the location map provide the section, township, and range and label section corners;

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

4. 2-06.4.7.A - Zoning and Land Use Notes

5. 2-06.4.7.A.4 - Revise General Note 3 to read "EXISTING USE PARKS AND RECREATION. PROPOSED USE PARKS AND RECREATION SUBJECT TO USE SPECIFIC STANDARDS 4.9.13.B & C.

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

6. 2-06.4.8.A - Provide site boundary/subdivision perimeter information, including bearing in degrees, minutes, and seconds

"2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

7. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined.


If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
11/06/2019 SBEASLE1 ZONING HC REVIEW Passed
11/06/2019 SBEASLE1 ENGINEERING REVIEW Reqs Change (comments from Okay to Submit)

DP19-0269

1) Require floodplain use permit. Fillable permit form sent to customer via email.

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
12/06/2019 ANDREW CONNOR LANDSCAPE REVIEW Approved
12/09/2019 MARTIN BROWN COT NON-DSD FIRE Approved
12/10/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
See details below - a resubmittal is required.

NOTE: All plan review counters will be closed during Christmas week, Dec. 23-27. However, the permit counter will be closed only on Dec. 25, and open the rest of the week from 8am-2pm, phone (520) 791-5550 press “O” for an operator.

Permit/Activity Number: DP19-0269
Include this number on all future correspondence.

Project Description: SITE - La Madera Park, COT, shade structure

Fees Due: $ 429.00
Note: We require a payment prior to accepting your next submittal.
Please pay the total fees (or Review Fees at a minimum):
1. Online Payment (Not available for "DS.." permit numbers)
2. In person at the City Permit Counter (Mon-Fri, 8:00 AM to 2:00 PM)
3. By mail - a check payable to the City of Tucson (address is below),
include the Activity Number

Online Payment
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. Total fees due: May take 1-2 days for information to be available
2. Visa, MC, Discover, American Express
3. Not case-sensitive but a hyphen is needed, for example: dp19-2000
4. Enter your Permit Nbr. and click the Continue tab
5. Business/Individual Name: Leave blank
6. If any issues, try using the browser Internet Explorer

To view documents and Reviewer's comments: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on "Review Details"

Submit the following items to the Filedrop.
In the Project Description field, enter the Activity Number.
PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
4) Name your 2nd submittal documents accordingly, for example: 2_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 3rd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
12/10/2019 SBEASLE1 OUT TO CUSTOMER Completed