Permit Number: DP19-0266
Parcel: 11615190M

Address:
1780 W ANKLAM RD

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP19-0266
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/30/2019 SBEASLE1 START PLANS SUBMITTED Completed
11/19/2019 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: Da Vita Dialysis West - Covered Parking
Development Package (1st Review)
DP19-0266

TRANSMITTAL DATE: October 30, 2019

DUE DATE: OK to Submit

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

2-06.3.0 FORMAT REQUIREMENTS

1. 2-06.3.12 - Revise the sheet index to reflect what has been submitted.

CONTENT REQUIREMENTS

2. 2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet.

3. 2-06.4.2.D - Revise the total number of sheets to reflect what has been submitted.

4. 2-06.4.3 - Provide the development package case number, DP19-0266 , adjacent to the title block on all sheets.

5. 2-06.4.2.C - For the location map provide the section, township, and range; and label the section corners.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

6. 2-06.4.7.A.1 - List as a general note: "Existing zoning is O-3."

7. 2-06.4.7.A.2 - List the gross area of the site/subdivision by square footage and acreage.

8. 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses.

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

9. 2-06.4.8.A - Provide site boundary perimeter information, including bearing in degrees, minutes, and seconds.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

10. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined.

11. 2-06.4.9.H.5 - Show the required 1' setback to the PAAL on the plan, see UDC Article 7.4.6.F.2.A.(1).

12. 2-06.4.9.O - Show the required perimeter yard setback dimension from the proposed covered parking to the north property line. Per UDC TABLE 6.3-3.A: DIMENSIONAL STANDARDS FOR THE O-1, O-2, & O-3 ZONES the required perimeter yard setback is 10 or ¾ the height, the greater of the two.

13. 2-06.4.9.Q - Provide the height of the proposed covered parking within the footprint of the structure.

14. Remove the architect/engineers stamp from the plans.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
11/26/2019 ANDREW CONNOR LANDSCAPE REVIEW Approved
12/03/2019 MARTIN BROWN COT NON-DSD FIRE Approved
12/03/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP19-0266

1) Placement of the proposed shade canopy appears to interfere with an existing trash enclosure and also with the existing location for solid waste service. Show on plans how existing service will be maintained

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
12/04/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is required.
Permit/Activity Number: DP19-0266
Include this number on all future correspondence.

Project Description: SITE - Da Vita Dialysis. New 10-space steel carport canopy.

Fee Balance: $0 (zero).
To view documents and Reviewer's comments: www.tucsonaz.gov/pro
(If information is not available, check back later as data transfers to PRO periodically.)
- Home page, left side, “Activity Search”, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on "Review Details"

Submit the following items to the Filedrop.
In the Project Description field, enter the Activity Number.
PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's “Requires Change” comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
4) Name your 2nd submittal documents accordingly, for example: 2_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 3rd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
12/04/2019 SBEASLE1 OUT TO CUSTOMER Completed