Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP19-0261
Parcel: 12406132A

Address:
1050 E 8TH ST

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0261
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/10/2020 SBEASLE1 START PLANS SUBMITTED Completed
01/17/2020 ELISA HAMBLIN ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Wildcat Village, 1050 E 8th St
Development Package (5th Review)
DP19-0261

TRANSMITTAL DATE: January 17, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is October 22, 2020.

1. As per previous comments, UDC Administrative Manual Section 2-06.4.9.H.5.a requires parking spaces and parking area access lanes to be designed to City standards. The illustrated parking does not meet standards. See comments below.
a. The parking to the north of the building includes one space over an existing sidewalk. However, detail 2 does not show the space over the sidewalk. Correct overall site plan to match detail 2.
b. It is acknowledged handicap accessible spaces have been provided that meet dimensional standards. The route to the building appears to be the correct size. Provide ramp detail (slope) to verify all standards are met. See Chapter 4 of the ICC A117.1-2009.
c. Provide dimensions (on detail 2 and overall site plan) for all sidewalks which provide access from parking areas to the building. Only some dimensions have been provided. Per Technical Standards Manual 7-01.3.A. "All sidewalks must be a minimum of four feet wide and installed to avoid any obstruction which decreases the minimum width to less than four feet."
d. Correct development information note 2. There are now 71 regular open sparking spaces and 4 accessible parking spaces on site. This total 75 parking spaces provided.

2. Previous comments not fully addressed. Changes to submittal 5 not adequate. Please call to discuss. UDC Administrative Manual Section 2-06.4.9.H.5.d - It is acknowledged the bicycle parking calculations have been corrected and additional dimensions have been provided on the plan. However, bicycle design standards are not being met. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Dimensions and maneuverability standards per the UDC must be met and illustrated on the development package. The short-term bike parking as illustrated does not work. Bikes parked on the racks would overhang onto the next rack. The long-term bike parking must meet location, security, weather protection, signage and lighting standards per the code. Again, refer to Section 7.4.9 of the UDC.

3. Comment 1.a.-d. in this transmittal regarding parking are minor and can be addressed on the next submittal. I am now confident on the total number of spaces provided. The applicant can proceed with the application for an the Individual Parking Plan (IPP) with 153 spaces required and 75 provided. Other needed corrections to the development package can be continued to be processed while the IPP is pending. However, final approval of the development package cannot be obtained until the IPP is approved.

If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov or (520) 837-4966.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
01/22/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICEA resubmittal with a Comment Response Letter is required.

DESCRIPTION: SITE - Wildcat Village, multi-family development.

PERMIT: DP19-0261 Please include this number on all future correspondence and in Filedrop's "Project Description" field.

MANAGER: Elisa.Hamblin@TucsonAz.gov or (520) 837-4966

FEES DUE: $ 412.50 (see Balance column in image below)Note: A payment is required before we can accept your next submittal.

Please pay the total fees:
1. Online Payment
2. In person at the City Permit Counter (Mon-Fri, 8:00 AM to 2:00 PM)
3. By mail - a check payable to the City of Tucson (address is below), include the Activity Number

Online Payment https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. NOTE: It may take 1-2 days for complete permit information to be available online
2. Visa, MC, Discover, American Express
3. Not case-sensitive but a hyphen is needed, for example: dp19-2000
4. Enter your Permit Nbr. and click the Continue tab
5. Business/Individual Name: Leave blank
6. If any issues, try using the browser Internet Explorer

VIEW DOCUMENTS and reviewer's comments on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on Review Details

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
- In the Project Description field, enter the Activity/Permit Number
- Name your 6th submittal documents accordingly, for example: 6_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 2nd Floor, Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
01/22/2020 SBEASLE1 OUT TO CUSTOMER Completed