Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP19-0259
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/24/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 11/20/2019 | SAMUEL ROGERS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Samuel Rogers - Planner PDSD Zoning Review Section PROJECT: Chick-Fil-A Drive-Thru Modifications Development Package (1st Review) DP19-0259 6675 E Grant Rd. TRANSMITTAL DATE: 11/20/19 DUE DATE: 11/22/2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is October 21, 2020. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) Section 2-06.3.0 FORMAT REQUIREMENTS 1. COMMENT: 2-06.3.4 - Provide the title block on the first sheet. 2. COMMENT: 2-06.4.2.D - Add "sheet 1 of 5" to the cover sheet. 3. COMMENT: 2-06.4.3 - The street direction is not provided for the administrative address, address should be 6675 E Grant Rd. Provide the development package case number, DP19-0259, adjacent to the title block on each sheet. 4. COMMENT: 2-06.4.4.C - Add the section corners at Wilmot & Speedway, Sppedway & Sabino Canyon, and Tanque Verde & Sabino Canyon. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. Zoning and Land Use Notes 5. COMMENT: 2-06.4.7.A.4 - Please add a reference to UDC use specific standards 4.9.4.M.1 and 4.9.13.P on Site Note 5. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 6. COMMENT: 2-06.4.8.A - Provide the curve data for the corner property boundary. 7. COMMENT: 2-06.4.8.C - Add the recording information on right-of-way adjacent to the site. (Grant Rd. Bk. 8 Pg. 45/Tanque Verde Rd. Bk. 1 Pg. 39) 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 8. COMMENT: 2-06.4.9.F - All existing zoning classifications adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined 9. COMMENT: 2-06.4.9.H.5.a - Provide the dimensions for the off street parking that is being altered. If you have any questions about this transmittal, Contact Samuel Rogers at (520) 837-6932 or by email Samuel.Rogers@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 11/21/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | ADMINISTRATIVE MANUAL 4.1 Identification and Descriptive Data The Development Package will contain the following identification in the lower right corner of each sheet: Any relevant case numbers for reviews or modifications that affect the site. Add case # DP19-0259 Ensure that all Zoning comments and concerns are addressed. Additional comments may apply. |
| 11/22/2019 | SROGERS2 | ZONING HC | REVIEW | Reqs Change | See zoning comments |
| 11/22/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 11/25/2019 | MARTIN BROWN | COT NON-DSD | FIRE | Approved | |
| 11/25/2019 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 11/29/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE - A resubmittal is required. Permit/Activity Number: DP19-0259 Include this number on all future correspondence. Project Description: SITE - Chick-Fil-A, drive-thru modification. Fee Balance: $0 (zero). To view documents and Reviewer's comments: www.tucsonaz.gov/pro (If information is not available, check back later as data transfers to PRO periodically.) - Home page, left side, “Activity Search”, enter the Activity Number - “Permits” section, click on blue tab - “Documents” section, click on blue icon to the right of each document - "Reviews" section, click on "Review Details" Submit the following items to the Filedrop. In the Project Description field, enter the Activity Number. PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's “Requires Change” comments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff 4) Name your 2nd submittal documents accordingly, for example: 2_Plan_Set Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/29/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |