Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP19-0250
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/16/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 01/16/2020 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Approved | |
| 01/17/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | The following applies: 5.4. MAJOR STREET AND ROUTES SETBACK ZONE (MS&R) 5.4.5. PERMITTED USE OF MS&R RIGHT-OF-WAY AREA An approved site plan is required indicating how the project will comply with UDC standards when the MS&R right-of-way can no longer be used as part of the site. Such plan shall be an exhibit to an executed covenant for recordation stating the responsibility of the property owner, successor, or assignee as to the removal of improvements and compliance with the UDC at no cost to the City. Minimum Width Street landscape borders must be a minimum of ten feet wide as measured from the street property line. On streets designated as Major Streets and Routes (MS&R), the street landscape border must be measured from the future MS&R right-of-way line as determined by Section 5.4.4. A future site plan will need to show how the site will meet minimum conditions of the UDC. The entire street buffer cannot be located in the future ROW along Oracle. Note: Any use of the ROW will need permission from ADOT Ensure that Zoning comments are addressed prior to landscape section approval. Additional comments may apply. |
| 01/30/2020 | MALLORY RESS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Mallory Ress, Planner PDSD Zoning Review Section PROJECT: La Frontera Alborada Apts - 2940 N Oracle Rd Development Package (3rd Review) DP19-0250 - C-2 Zoning TRANSMITTAL DATE: January 30, 2020 DUE DATE: February 13, 2020 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. All previous zoning comments have been addressed. Address landscaping comments. Zoning will review next plan site to ensure compliance with zoning and site requirements. Additional comments may be forthcoming. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson "Unified Development Code" - Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, Contact Mallory Ress at (520) 837-6933 or by email Mallory.Ress@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 01/30/2020 | MRESS1 | ZONING HC | REVIEW | Reqs Change | |
| 01/30/2020 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE DESCRIPTION: SITE/GRADING - La Frontera Alborada Apts. - Oracle, single-story. PERMIT: DP19-0250 Please include this number on all future correspondence and in Filedrop's "Project Description" field. PROJECT MANAGER: Mallory.Ress@Tucsonaz.gov or (520) 837-6933 FEE BALANCE: $0 (zero) VIEW DOCUMENTS and reviewer's comments on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Documents section, click on blue icon to the right of each document - Reviews section, click on Review Details YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff - Filedrop: In the Project Description field, enter the Activity/Permit Number - Name your 4th submittal documents to start with the number, for example: 4_Plan_Set Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, 2nd Floor Tucson, AZ 85701 email: COTDSDPermits@TucsonAz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/30/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |