Permit Number: DP19-0250
Parcel: 10712170G

Address:
2940 N ORACLE RD

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0250
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/06/2020 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL

SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS

4.1 Identification and Descriptive Data

All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

The future ROW was not indicated along Oracle in previous reviewed landscape plan.

Show the future ROW on the Landscape Plan

The following applies:

5.4. MAJOR STREET AND ROUTES SETBACK ZONE (MS&R)

5.4.5. PERMITTED USE OF MS&R RIGHT-OF-WAY AREA

An approved site plan is required indicating how the project will comply with UDC standards when the MS&R right-of-way can no longer be used as part of the site. Such plan shall be an exhibit to an executed covenant for recordation stating the responsibility of the property owner, successor, or assignee as to the removal of improvements and compliance with the UDC at no cost to the City.

Note: Oracle is an ADOT ROW

Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.


Additional comments may apply.
01/07/2020 MRESS1 ZONING HC REVIEW Reqs Change
01/07/2020 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP19-0250

1) Show that the curb access ramp at the northwest corner (Blacklidge and N Oracle Rd) of the development will be updated to the latest PAG standard detail 207
2) The proposed retention basins along N Oracle Road are located entirely within the future right of way. Show how the site will function when the future right of way has been taken, which would include the removal of the basins

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
01/07/2020 MALLORY RESS ZONING REVIEW Reqs Change CDRC TRANSMITTAL
TO: Development Services Department
Plans Coordination Office

FROM: Mallory Ress, Planner
PDSD Zoning Review Section
PROJECT: La Frontera Alborada Apts - 2940 N Oracle Rd
Development Package (2nd Review)
DP19-0250 - C-2 Zoning
TRANSMITTAL DATE: January 7, 2020
DUE DATE: January 7, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is October 10th, 2020.
SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

1. COMMENT: 2-06.4.9.H.5.a - General Note 18 indicates that a portion of the reduction of required motor vehicle parking spaces is obtained by additional long term bicycle parking located within one bedroom units and two/three bedroom units. General note 18 also states that the project is for 14 one bedroom units. Clarify and correct as necessary.

2-06.4.9.J - If street dedication is not required or proposed and the project site is adjacent to a Major Street or Route, draw the Major Street right-of-way lines for those streets. (Add the MS&R future sidewalk, right-of-way lines, sight visibility triangles, etc.)

2. COMMENT: 2-06.4.9.J - It is acknowledged that future ROW is shown on the plan. Recommend verifying future center line location with Tucson Department of Transportation. See Engineering comments regarding detention basins within future right of way. Additional comments may be forthcoming.

2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual.

3. COMMENT: 2-06.4.9.R - It is acknowledged that a TSMR was approved for pedestrian circulation on Blacklidge Dr. Include the activity number, DS19-32, in the title block. Per Section 4.7.A.6.a, include a general note describing the approved modification under DS19-32, date of approval, and any conditions.

***For additional information on the any standard presented in this memo, please refer to the City of Tucson "Unified Development Code" - Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations

If you have any questions about this transmittal, Contact Mallory Ress at (520) 837-6933 or by email Mallory.Ress@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
01/08/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
NOTE: A resubmittal with a Comment Response Letter is required.
Permit/Activity Number: DP19-0250
Please include this number on all future correspondence.

Description: SITE/GRADING - La Frontera Alborada Apts. - Oracle, single-story.
Manager (PDSD): Mallory.Ress@TucsonAz.gov

Fee Balance: $0 (zero)
View documents and reviewer's comments on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on Review Details

Your next step: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
- In the Project Description field, enter the Activity Number
- Name your 3rd submittal documents accordingly, for example: 3_Plan_Set

1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 2nd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov
12/06/2019 SBEASLE1 START PLANS SUBMITTED Completed
12/24/2019 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved DP19-0250 / 2nd submittal/ La Frontera Alborada Apts is Approved by Pima County Addressing.
Thank you,
Robin Freiman, Addressing Official
Pima County Development Services Department
201 N Stone AV – 1st Floor Tucson, AZ 85701, (520) 724-7570

Final Status

Task End Date Reviewer's Name Type of Review Description
01/08/2020 SBEASLE1 OUT TO CUSTOMER Completed