Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - OK TO SUBMIT
Permit Number - DP19-0243
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/07/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 10/07/2019 | SBEASLE1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Passed | |
| 10/07/2019 | SBEASLE1 | WWM | REVIEW | Passed | |
| 10/09/2019 | SSHIELD1 | ENGINEERING | REVIEW | Approved | |
| 10/09/2019 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Section Manager PROJECT: 600 W Saint Mary's Road Development Package (1st Review) DP19-0243 TRANSMITTAL DATE: October 9, 2019 DUE DATE: OK to Submit COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is October 5, 2020 2-06.2.1 APPLICATION SUBMITTAL REQUIREMENTS 1. 2-06.2.4 - As the structural sheets are not part of the development package remove sheets S2.0, S5.0, S6.0 & S6.1 from the development package plan set. Sheet S5.0 should be provided as an individual sheet for reference only. 2-06.3.0 FORMAT REQUIREMENTS 2. 2-06.3.12 - Once the sheets mentioned in comment 1 above have been removed revise the sheet index accordingly. 2-06.4.0 CONTENT REQUIREMENTS 3. 2-06.4.7.A.6 - Per Administrative Directive 1.07-7 Protection of Archaeological and Historical Resources in City Projects, Section 1.07-7.II.B Departments shall ensure that no land leveling, grading or excavation occurs on City projects, and no designated historic structures or potentially historic structures are altered or demolished, without first receiving clearance for such activities in accordance with the provisions of this directive. As the park is City owned property Archaeological review is required prior to approval of this plan. Contact Jodie Brown, 520-837-6968 for review requirements. 4. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 5. 2-06.4.9.O - Per UDC Table 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-3 zone when a Nonres use is adjacent to a residential zone the required perimeter yard setback is 10' or ¾ the height of the structure. That said based on a height of 24'-3" the required perimeter yard setback to the south property line should be 18'-2". Per UDC Article 6.6.2.D An accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). Provide the required signoff on the development package. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 10/10/2019 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Completed |