Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - OK TO SUBMIT
Permit Number - DP19-0236
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/03/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
10/03/2019 | SBEASLE1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Passed | |
10/03/2019 | SBEASLE1 | WWM | REVIEW | Passed | |
10/04/2019 | ALEXANDRA HINES | ZONING-DECISION LETTER | WRITE DECISION LETTER | Needs Review | PLAN ACCEPTED FOR REVIEW NOTICE Permit/Activity Number: DP19-0236Review Start Date (20 working days): October 4, 2019Description: SITE - Pinnacle Realty, parking. Fees Due: $346.50 (see the image below) Please pay the total fees (or Review Fees at a minimum):1. Online2. In person at the Permit Counter (Mon-Fri, 8:00 AM to 2:00 PM)3. By mail - a check payable to the City of Tucson, address is shown below, include the Activity Number NEW: Online payments are now accepted. 1. Visa, MC, Discover, or American Express2. No cost to the customer3. All data and transactions are securely encrypted 4. City staff cannot view your online payments Link to Online Payments:https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records1. Not case-sensitive but a hyphen is needed, e.g.: dp19-00002. Simply enter your Permit Nbr. and click the “Continue” tab3. If any issues, try using the browser Internet Explorer. You may view your submitted documents and the reviewer's comments at www.tucsonaz.gov/pro (If information is not listed, check back later as data flows to PRO periodically throughout the day.)- “Activity Search” (Home page, left side), enter the Activity Number- “Permits” section, click on blue tab- “Documents-PDFs” section, click on the small blue icon to the right of each document- "Reviews" section, click on "Review Details" After all reviews are completed, we will send an email notification. NOTE: Over-the-counter reviews may be available for some City reviews - at the City staff’s discretion. Before visiting the City office, please contact the reviewers via phone or email. See the reviewer's comments in PRO for contact information: www.tucsonaz.gov/pro. PDSD Hours: https://www.tucsonaz.gov/pdsd/contact-us-hours-service Thank you. Alexandra Hines |
10/04/2019 | SSHIELD1 | ENGINEERING | REVIEW | Approved | |
10/04/2019 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Section Manager PROJECT: Pinnacle Realty Development Package (1st Review) DP19-0236 TRANSMITTAL DATE: October 4, 2019 DUE DATE: OK to Submit COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is October 3, 2020, 2020. 2-06.3.0 FORMAT REQUIREMENTS 1. 2-06.3.5 - A three-inch by five-inch space shall be reserved in the lower right quadrant of each sheet for an approval stamp. CONTENT REQUIREMENTS 2. 2-06.4.3 - Provide the development package case number, DP19-0236, adjacent to the title block on all sheets. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 3. 2-06.4.9.H.5.a - The proposed reduction to the number of required vehicle parking space not correct. Per UDC Article 7.4.5.E.1.d The required number of spaces for individuals with physical disabilities is based on the total number of motor vehicle parking spaces required before any reduction has occurred. That said the total number of vehicle parking spaces required prior to any reductions is 27 spaces. Per 2018 IBC Table 1106.1 when 27 vehicle parking spaces are provided 2 accessible spaces are required therefore you would need to provide a total of three (3) to use the reduction allowed in UDC Article 7.4.5.E.2. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |