Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP19-0231
Parcel: 109224480

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0231
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/22/2019 SBEASLE1 START PLANS SUBMITTED Completed
11/22/2019 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Completed Addressing does not need to review this project.
Thank you.
Nicholas Jordan, Addressing Specialist
Pima County Development Services Department
201 N Stone AV – 1st Floor, Tucson, AZ 85701, (520) 724-9623
12/05/2019 IMONSHI1 ZONING HC REVIEW Reqs Change
12/05/2019 IMONSHI1 ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Iman Monshizadeh
PDSD Zoning Review Section

PROJECT: Improvement Plans Chase Bank
Development Package (2nd Review) - PAD-22
DP19-0231 - 3570 N Craycroft Rd

TRANSMITTAL DATE: December 5th, 2019
DUE DATE: December 23rd, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is September 27th, 2020.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

1. COMMENT: 2-06.4.9.H.5 - according to section III.G.1.b of the Rio Verde Village PAD, PAALs for non-residential uses must have a minimum width of 24'. The PAAL shown on C-3 to the west of the building shows a width of 22'. Revise the PAAL length on the next submittal and provide dimensions for the standard parking spaces adjacent to that PAAL to show that they still meet the required parking spot size.

Refer to DP15-0065, the last approved DP for the previous Kneaders Bakery shows a 24' PAAL with typical parking dimensions on the existing spaces adjacent to the PAAL west of the building.

2. COMMENT: Remove all deltas and clouds from the DP on the next submittal


***For additional information on the any standard presented in this memo, please refer to the City of Tucson "Unified Development Code" - Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations


If you have any questions about this transmittal, Contact Iman Monshizadeh at (520) 837-4082 or at Iman.Monshizadeh@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
12/18/2019 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Reqs Change Comment not addressed. At the time of DP19-0231 resubmittal, upload required DRC letter with DP19-0231 upload.

The Rio Verde Village Planned Area Development states that under Section Ill, L. of the Design Review Committee on Pg. 96 states the following: The DRC shall review all proposed architectural plans. Through a self-certification process, the DRC will provide a letter of approval to the city at the time of plan submittal. The applicant must provide a letter of approval from the Design Review Committee for all proposed architectural plans, at the time of plan resubmittal. Please
Submit required DRC letter for plan review.
12/19/2019 ANDREW CONNOR LANDSCAPE REVIEW Approved
12/20/2019 LOREN MAKUS ENGINEERING REVIEW Approved
12/30/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
12/31/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
NOTE: A resubmittal with a Comment Response Letter is required.

Permit/Activity Number: DP19-0231
Include this number on all future correspondence.

Project Description: SITE/GRADING - Chase Bank.
Fee Balance: $0 (zero)
View the documents and the reviewer's comments online: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on "Review Details"

Submit the following items to the Filedrop.
In the Project Description field, enter the Activity Number.
PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
4) Name your 3rd submittal documents accordingly, for example: 3_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

NOTE: All City of Tucson offices will be closed on Wednesday, January 1 (except for emergency services). Planning & Development Services will be open normal business hours on Thursday and Friday: https://www.tucsonaz.gov/pdsd/contact-us-hours-service.

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 2nd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
12/31/2019 SBEASLE1 OUT TO CUSTOMER Completed