Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP19-0227
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/27/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 10/08/2019 | MESCALA1 | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Martin Escalante PDSD Zoning Review Section PROJECT: Gates Development Package (1st Review) DP19-0227 -Zoning R-3 TRANSMITTAL DATE: October 7, 2019 DUE DATE: October 25, 2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is October 25, 2020. 2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. 1. COMMENT: 2-06.4.3 - Provide the development package case number, DP , adjacent to the title block on each sheet. 2-06.4.9.H.3 - Indicate fire circulation, including accessibility and vehicle maneuverability. 2. COMMENT: 2-06.4.9.H.3 - Provide fire circulation, including accessibility and vehicle maneuverability. 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. 3. COMMENT: 2-06.4.9.H.5.a - Provide updated calculations on the number of spaces required and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. Note**Provide updated parking analysis from the approved site plan. If you have any questions about this transmittal, Contact Martin Escalante by email at Martin.Escalante@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 10/11/2019 | MASHFOR1 | COT NON-DSD | FIRE | Approved | TFD Lock Box is noted on first page of DP |
| 10/23/2019 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 10/24/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 10/29/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 10/30/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE - A resubmittal is required. Permit/Activity Number: DP19-0227 Project Description: SITE - Crown Villas Apts, electric gate and fence. Fee Balance: $0 (zero). Thank you for the payment. View the reviewer's comments: www.tucsonaz.gov/pro (If information is not available, check back later as data transfers to PRO periodically.) - Home page, left side, “Activity Search”, enter the Activity Number - “Permits” section, click on blue tab - "Reviews" section, click on "Review Details" Submit the following items to the Filedrop. Before uploading, please enter the Activity Number in the Project Description field. PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's “Requires changes” comments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff 4) Name your 2nd submittal documents accordingly, for example: 2_Plan_Set Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/30/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |