Permit Number: DP19-0226
Parcel: 116214500

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Permit Number - DP19-0226
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/26/2020 SBEASLE1 START PLANS SUBMITTED Completed
03/31/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
03/31/2020 ANDREW CONNOR LANDSCAPE REVIEW Approved
04/09/2020 DJELLEN1 ZONING REVIEW Reqs Change CDRC TRANSMITTAL



TO: Development Services Department

Plans Coordination Office



FROM: David Jellen

PDSD Zoning Review Section



PROJECT: Sentinel Vista Lots 1-11

Development Package (2nd Review)

DP19-0226



TRANSMITTAL DATE: April 9, 2020



COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.



Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is September 24, 2020.



SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

Section



2-06.3.0 FORMAT REQUIREMENTS



CONTENT REQUIREMENTS



2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.



COMMENT: Revise the shared common parking area so that it meets ADA accessibility standards.





If you have any questions about this transmittal, contact David Jellen at David.Jellen@tucsonaz.gov.



RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/10/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change No backwater valves are shown on sheets 7 and 8. [Second comment: Fixtures located 12" or more above the rim elevation of the next upstream manhole may not discharge through a backwater valve. Lots 1, 2, and 8 appear to be more than 12" above the rim elevation of the next upstream manhole. Reference: Section 714.1, IPC 2018. [Initial comment: Indicate which lots require the installation of backwater valves. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.]
04/21/2020 SBEASLE1 PIMA COUNTY ADDRESSING Approved DP19-0226, Tentative Plat Sentinel Vistas, 3rd submittal is Approved by Pima County Addressing.

Please note a street name for the private road should be submitted to addressing@pima.gov for review to be reserved for the Final Plat.

Let me know if you have any questions. Thank you,
Robin Freiman, Addressing Official

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
04/21/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change RETURNED FOR CORRECTIONS NOTICE
Your Next Steps: Resubmittal with a Comment Response Letter

DESCRIPTION: TENTATIVE PLAT/FLD - Sentinel Vistas, Lots 1-11, CA "A" (priv road and parking), CA "B" (landsc and drainage), CA "C" (open space and drainage).

PERMIT: DP19-0226
FEE BALANCE: $0 (zero)

SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Reviews section, click on Review Details
- Documents section, click on blue icon to the right of each document

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Name your 4th submittal documents to start with the submittal number, for example: 4_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov

NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue (the physical office) is closed to the public until further notice. In the meantime, our staff is working remotely from home. All communications are by telephone or email.

CONTACT US: To speak with a staff member on the telephone,
please sign into the Virtual Zoning Counter: https://www.tucsonaz.gov/pdsd/virtual-walk-thru.
The queue is open from 8:00 am -12:00 noon, Monday-Friday.
It’s better to sign in closer to 8 than 12 noon.
This is similar to the City’s in-person counter.
The difference is after you sign up, we will give you a call.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/21/2020 SBEASLE1 OUT TO CUSTOMER Completed