Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP19-0219
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/12/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 12/16/2019 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Revise the site drawing to include the following existing utility information: a. The location and size of sanitary and storm sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number. b. The first floor elevation for the building. Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2018. |
| 12/16/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP19-0219 Previous comments 1-3 1) Show on plans a curb access ramp meeting PAG standard Detail 207 at Corner of Hoff Av and E 7th St 2) The existing curb cut just south of the "Loading" area will need to be closed off if it is being abandoned. Reference Tucson City code section 25-43. If the curb cut is being used to access the Loading area show on plans that it will be updated to PAG standard Detail 206 3) Show on plans the cross slope and running slope for existing sidewalk along E 7th St and N 4th Av. Any sidewalk not meeting current ADA standards, or which is in a state of disrepair, will need to be replaced according to PAG standard detail 200 |
| 12/19/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE See details below - a resubmittal is required. Permit/Activity Number: DP19-0219 Include this number on all future correspondence. Project Description: SITE / IID - Bawker Bawker Cider House, bar, taproom. Project Manager: Nicholas.Ross@TucsonAz.gov, (520) 837-4029 Fee Balance: $0 (zero) To view documents and Reviewer's comments: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Documents section, click on blue icon to the right of each document - Reviews section, click on "Review Details" Submit the following items to the Filedrop. In the Project Description field, enter the Activity Number. PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff 4) Name your 3rd submittal documents accordingly, for example: 3_Plan_Set HOLIDAY SCHEDULE, Dec. 23-27 (Mon-Fri): All City of Tucson Planning and Development permitting services and Cashier Services at the Public Works Blg., 201 N. Stone Ave., (first floor) will be closed. Beginning Dec. 30 (Mon), they will reopen at their new location on the second floor. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, 3rd Floor Tucson, AZ 85701 email: COTDSDPermits@TucsonAz.gov |
| 12/19/2019 | NROSS1 | LANDSCAPE | REVIEW | Reqs Change | |
| 12/19/2019 | NICHOLAS ROSS | ZONING | REVIEW | Reqs Change | |
| 12/19/2019 | NROSS1 | ZONING HC | REVIEW | Reqs Change | |
| 12/19/2019 | NROSS1 | DESIGN PROFESSIONAL | REVIEW | Reqs Change |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/19/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |