Permit Number: DP19-0218
Parcel: 14118530C

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP19-0218
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/11/2019 SBEASLE1 START PLANS SUBMITTED Completed
09/13/2019 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: Tusimple Expansion
Development Package (1st Review)
DP19-0218

TRANSMITTAL DATE: September 13, 2019

DUE DATE: October 09, 2019
COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is September 8, 2020.

CONTENT REQUIREMENTS

1. 2-06.4.3 - Provide the development package case number, DP19-0218, adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2. 2-06.4.7.A.6 - General Note 22 remove the reference to "GATEWAY CORRIDOR ZONE" as it is not applicable.

2-06.4.7.A.8 - For development package documents provide:

3. 2-06.4.7.A.8.c - It appears that you have provided a vehicle use area expansion calculation, provide a site area expansion calculation on the plan.

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

4. 2-06.4.8.B - Based on the Rita Ranch Commerce Center plat there are several easements located on the southern parcel. Show and label all easements on the plan.

5. 2-06.4.8.C - Provide a dimension from the curb to property line.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

6. 2-06.4.9.E - As this site is comprised of two (2) parcel a lot combination is required. Provide a copy of the approved Pima County combo form with your next submittal.

7. 2-06.4.9.H.2 - It does not appear that the existing SVTs are shown correctly. Also provide future SVTs base on the MS&R 90' cross section.

8. 2-06.4.9.H.5.a - Show and dimension the proposed 2'-6" vehicle overhang for all proposed vehicle parking spaces.

9. 2-06.4.9.H.5.a - Grading detail 1 provide spot grades so that slope requirements for the entire accessible vehicle parking space can be verified.

10. 2-06.4.9.H.5.a - Clearly show that the required two (2) van accessible vehicle parking spaces are provided.

11. 2-06.4.9.H.5.a - Per UDC Article 7.4.6.D.2.b Minimum Width Requirement When Adjacent to Barrier. A motor vehicle off-street parking space must have a minimum width of ten feet when the side(s) of the parking space abuts a vertical barrier over six inches in height, other than a vertical support for a carport. That said provide a dimension from the proposed hand rails shown near the center of the proposed vehicle parking area.

12. 2-06.4.9.H.5.c - The loading space calculation appears to be incorrect. Zoning was able to find 2 loading spaces clarify where the other 8 spaces are located at.

13. 2-06.4.9.J - Show the future sidewalk and curb on the plan and provide dimensions.

14. 2-06.4.9.L - If applicable show any proposed easements on the plan along with the recordation information.

15. 2-06.4.9.O - It does not appear that the street once perimeter yard setback is shown correctly. Once comment 13 is addressed the setback can be clearly shown.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
09/13/2019 SSHIELD1 ZONING HC REVIEW Reqs Change See Zoning comments
10/01/2019 MASHFOR1 COT NON-DSD FIRE Approved
10/07/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL

All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

The landscape plan will contain the following identification in the lower right corner of each sheet:

Any relevant case numbers for reviews or modifications that affect the site.

Provide Case # DP19-0218 on each sheet.

7.6. LANDSCAPING AND SCREENING

7.6.2. APPLICABILITY

Expansion of existing development, as provided below:

1. Buildings Greater Than 10,000 Square Feet
On sites where the gross floor area of the existing building(s) is more than 10,000 square feet, expansion in square footage of land area, floor area, lot coverage, or vehicular use area as follows:

a. If the expansion is less than 25%, the standards of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning standards in effect at the time the existing development received zoning approval.
b. If the expansion is 25% or greater or if expansions as of February 15, 1991, cumulatively result in a 25% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the standards of this section apply to the entire site.

Vehicular Use Areas
1. Canopy Trees in Vehicular Use Areas

a. General Standards

Within a vehicular use area, one canopy tree is required for each four motor vehicle parking spaces or fraction thereof.

(1) The canopy trees must be evenly distributed throughout the vehicular use area. Every parking space must be located within 40 feet of the trunk of a canopy tree (as measured from the center of the tree trunk).

Verify that existing vehicular use area meets canopy tree requirement.

Ensure that all Zoning and Engineering comments and concerns are addressed.


Additional comments may apply.
10/14/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
10/18/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP19-0218

1) Update the drainage report and development package so that the curb openings into the water harvesting areas match. For example the water harvesting area identified in detail K/7 shows one 4' wide curb opening in the drainage report whearas the development plan specifies two 2' wide curb openings
2) Sheet 12. Site Water Budget Table indicates the average depth of the water harvesting basins to be 1' deep. General Note 3 indicates 6". Plans call for basins to be 9" deep. Update as needed
3) Sheet 12. Verify that the volumes stated in the Site Water Budget take into account the constructed condition of the basin, which includes side slopes and placement of ground cover

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
10/21/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is required
Permit/Activity Number: DP19-0218
Project Description: SITE/GRADING/SWPPP - TuSimple Expansion, new driveway and parking areas.
The fee balance is $0 (zero). Thank you for the payment.
To view the review comments: www.tucsonaz.gov/PRO, enter the Permit/Activity Number.
(If information isn't shown yet, check back later as data uploads to PRO periodically.)
Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (your response to the reviewer's “Requires changes” comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
4) Name your 2nd submittal documents accordingly, for example: 2_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
10/21/2019 SBEASLE1 OUT TO CUSTOMER Completed