Permit Number: DP19-0215
Parcel: 112064130

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP19-0215
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/10/2019 SBEASLE1 START PLANS SUBMITTED Completed
09/10/2019 SAMUEL ROGERS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: Blue Willow Restaurant and Gift Shop
Development Package (1st Review)
DP19-0215

TRANSMITTAL DATE: 9/10/2019
DUE DATE: 9/24/2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is September 10, 2020.



2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet.

1. COMMENT: Provide the development package case number, DP19-0215, adjacent to the title block on each sheet.

2. COMMENT: Add all slope details for ADA accessibility or note indicating no change is slope.

3. COMMENT: Update address to 2614 N Campbell Av.





If you have any questions about this transmittal, Contact Paul Camarena at (520) 791-5550 or by email Paul.Camarena@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
09/10/2019 SROGERS2 ZONING HC REVIEW Reqs Change See zoning comment
09/10/2019 JOHN VAN WINKLE ENGINEERING REVIEW Approved
09/12/2019 MASHFOR1 COT NON-DSD FIRE Approved
09/30/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is required
Permit/Activity Number: DP19-0215
Project Description: SITE - Blue Willow Restr., parking spaces.
The fee balance is $0 (zero). Thank you for your payment.
To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number.
(If information isn't shown yet, check back later as data uploads to PRO periodically.)
Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (listing your response to reviewer's comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
4) Name your 2nd submittal documents accordingly, for example: 2_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
09/30/2019 SSHIELD1 LANDSCAPE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
09/30/2019 SBEASLE1 OUT TO CUSTOMER Completed