Permit Number: DP19-0212
Parcel: 12616303A

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP19-0212
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/09/2019 SBEASLE1 START PLANS SUBMITTED Completed
09/10/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change The following information must be provided on the plans:

Square footage of the vehicular use area; number of parking spaces, including the required and provided parking space calculations; and the calculation of the required number of canopy trees.
09/10/2019 SARAH MEGGISON ZONING REVIEW Reqs Change Conditional Approval pending verification of existing parking spaces under covered canopies. Elisa to review resubmittal over the counter.
09/10/2019 SMEGGIS1 ZONING HC REVIEW Reqs Change See zoning comments.
09/10/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP19-0212

1) Detail 3 sheet 1. Ground clearance to lowest sign should be 7.
2) Detail 4 sheet 1. Detectable warnings are required at all curb access ramps per ICC A117.1
3) update reference building codes IBC 2018

engineering can conduct an over the counter electronic review once the above comments have been adressed and a new work flow opened
09/12/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is requested

Permit/Activity Number: DP19-0212
Description: SITE - The Ivy Apts, add new parking spaces.
Fees Due: $1,206.50
Note: Review fees must be paid before we can accept a resubmittal.

Please pay the total fees (or Review Fees at a minimum):
1. Online
2. In person at the permit counter (Mon-Fri, 8:00 AM to 2:00 PM)
3. By mail - a check payable to City of Tucson, address is shown below, include the Activity Number
City of Tucson - Online Payments:
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. Payment portal may take 1-2 days to update to the correct total fees due.
2. Not case-sensitive but a hyphen is needed, e.g.: dp19-0000
3. Enter your Permit Nbr. and click the “Continue” tab
4. If any issues, try using the browser Internet Explorer.
5. Accepted: Visa, MC, Discover, or American Express
6. All data and transactions are securely encrypted

To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number.
(If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.)
Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (listing your response to reviewer's comments)
2) Plan Set (all pages, full set)
3) Any other items requested by review staff
Name your 2nd submittal documents accordingly, for example: 2_Plan_Set.
Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
09/12/2019 MASHFOR1 COT NON-DSD FIRE Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
09/12/2019 SBEASLE1 OUT TO CUSTOMER Completed