03/30/2020 SBEASLE1 START PLANS SUBMITTED Completed
04/14/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
04/22/2020 SSHIELD1 LANDSCAPE REVIEW Approved
04/23/2020 STEVE SHIELDS ZONING REVIEW Approved
04/27/2020 LOREN MAKUS ENGINEERING REVIEW Reqs Change DP19-0210
1. The erosion hazard setback is measured from the top of bank of the wash. Revise the drainage statement exhibit and the development package site plans to clarify the setback throughout the site.
2. Callout for Keynote H is used on plan sheet 2. Include H in the list of notes.
3. Hydrology note on sheet 2 indicates water harvesting calculation is provided by civil engineer. Provide the calculation as referenced.
4. APC service along a Major Street requires permission from the Director of Environmental Services. Provide a copy of the permission granted by ES.
5. Driveways to a Major Street arterial must be provided with 25-foot radius curb returns.
6. The grading plan shows a 50-foot setback from the centerline of the wash. This means nothing and should be removed. Show the erosion hazard setback from the bank of the wash as described in the drainage statement.
7. Show drainage patterns on the grading plan. Provide enough proposed spot grades to demonstrate the drainage patterns will work as shown.
8. Clearly label the existing grades to show extent of grading. Since there is as much as two feet of fill within the banks of the wash, a complete encroachment analysis is required.
Loren Makus, EIT
Loren.makus@tucsonaz.gov
04/28/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change RETURNED FOR CORRECTIONS NOTICE
Your Next Step: Resubmittal of documents

DESCRIPTION: SITE/GRADING - Diamond Motors, car lot with office.
PERMIT: DP19-0210
PROJECT MANAGER: Samuel.Rogers@TucsonAz.gov
FEE BALANCE: $0 (zero)

SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Reviews section, click on Review Details
- Documents section, click on blue icon to the right of each document

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Name your 3rd submittal documents to start with the submittal number, for example: 3_Plan_Set

NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue (the physical office) is closed to the public until further notice. In the meantime, our staff is working remotely from home. All communications are by telephone or email.

CONTACT US INFO: To speak with a Permit Counter staff member on the telephone, please sign into the Virtual Zoning Counter:
https://www.tucsonaz.gov/pdsd/virtual-service-counter
The queue is open from 8:00 am -12:00 noon, Monday-Friday.
TIP: It’s better to sign in closer to 8 than 12 noon.
This is similar to the City’s in-person counter but instead over the phone.

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
04/28/2020 SBEASLE1 OUT TO CUSTOMER Completed