Permit Number: DP19-0209
Parcel: 13216600B

Address:
4300 S PARK AV

Review Status: Completed

Review Details: DEV PKG - OK TO SUBMIT

Permit Number - DP19-0209
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/29/2019 SBEASLE1 START PLANS SUBMITTED Completed
08/29/2019 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Passed
08/29/2019 LOREN MAKUS ENGINEERING REVIEW Passed
09/03/2019 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Steve Shields, Section Manager

PROJECT: COT Ward 5 - Covered Parking with Solar
Development Package (1st Review)
DP19-0209

TRANSMITTAL DATE: September 03, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

1. 2-06.3.5 - A three-inch by five-inch space shall be reserved in the same location on all sheets near the lower right quadrant of each sheet for an approval stamp.

2. 2-06.3.12 - The sheet index needs to be revised to correctly reflect what is submitted with the DP

2-06.4.2 - The title block shall include the following information and be provided on each sheet:

3. 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx).

4. 2-06.4.3 - Provide the development package case number adjacent to the title block on all sheets.

5. 2-06.4.4 - The project-location map to be located on the first sheet of the development package in the upper right corner, shall cover approximately one square mile, be drawn at a minimum scale of three inch equals one mile, and provide the following information.
2-06.4.4.A - Show the subject property approximately centered within the one square mile area;
2-06.4.4.B - Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property; and,
2-06.4.4.C - Section, township, and range; section corners; north arrow; and the scale will be labeled.

6. 2-06.4.5 - The sheet index needs to be revised to correctly reflect what is submitted with the DP.

7. 2-06.4.8.A - Provide site boundary perimeter information, including bearing in degrees, minutes, and seconds.

8. 2-06.4.9.Q - Provide a height dimension from the mid-point of the canopy to grade. Per UDC Article 6.6.3.C SPECIFICALLY WITHIN RESIDENTIAL ZONES - Accessory structures shall not exceed 12 feet in height, unless attached to a principal structure. It appears that the proposed structures exceed the allowed 12 height and will require a Board of Adjustment for Variance.



If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
09/03/2019 SBEASLE1 WWM REVIEW Passed