Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - OK TO SUBMIT
Permit Number - DP19-0207
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/27/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 08/27/2019 | SBEASLE1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Passed | |
| 08/27/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 09/03/2019 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields, Section Manager PROJECT: Walmart - 2711 S Houghton DP19-0207, Development Package TRANSMITTAL DATE: September 03, 2019 The development package has been reviewed by the Zoning Review Section for minimal compliance with the Administrative Manual Section 2-06. It has been determined that the submitted plans do not provide sufficient information to complete a plan review. The following items need to be addressed prior to re-submittal. The development package is designed to allow for concurrent review of any site related reviews. Concurrent review means that all plans and documents needed for the review are submitted as one package. Examples of site related reviews include but are not limited to: site plans, landscape plans, NPPO plans, water harvesting plans, grading plans, SWPPP plans, floodplain use permits, and overlay reviews. Remove all sheets not associated with the site from this development package. Remove all references to building code from the development package sheets. FORMAT REQUIREMENTS 1. Provide a small, project-location map in the upper right corner of the cover sheet. This map shall cover approximately one square mile, be drawn at a minimum scale of three inch equals one mile, and provide the following information; a. Show the subject property approximately centered within the one square mile area. Identify major streets within the square mile area and all streets that abut the subject property. Section, township, and range, north arrow, and the scale will be labeled. 2. Revise the drawing index to only include relevant development package sheets. Remove all reference to building plan sheets. 3. Provide the page number and the total number of pages in the package (i.e., sheet xx of xx). CONTENT REQUIREMENTS 1. The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines. GENERAL NOTES The following general notes are required. Additional notes specific to each plan are required where applicable. 1. "Existing zoning is ____." 2. List the gross area of the site by square footage and acreage. 3. Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. 4. Floor area for each building. EXISTING SITE CONDITIONS: 1. Provide site boundary information, including bearing in degrees, minutes, and seconds, together with distances in feet, to hundredths of a foot, or other functional reference system. 2. All existing easements shall be drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. 3. The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks. INFORMATION OF PROPOSED DEVELOPMENT: The following information on the proposed project shall be shown on the drawing or added as notes. 1. All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. 2. As vehicle parking is being removed to provide the pickup spaces a note, providing calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. 3. Provide a note on the plan stating "ALL SIGNAGE REQUIRES A SEPARATE PERMIT". The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 09/03/2019 | SBEASLE1 | WWM | REVIEW | Passed |