Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP19-0205
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/07/2020 | MRESS1 | DDO Prep | DRB HEARING DATE | Approved | |
| 01/16/2020 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera PDSD Zoning Review Section PROJECT: DP for Mattress Factory / Shopping Center development (Retail) Development Package (2nd Review) 1021 S. 6th Avenue DP19-0205 - C-3 Zoning TRANSMITTAL DATE: January 15, 2020 DUE DATE: January 21, 2020 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is August 22, 2020. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) ***Address remaining comments 1 and 2 and resubmit DP plans for review. (Previous comments noted below are for reference.) 1. Comment: Previous Comment 7 is still applicable until the PC Tax Parcel Combo Documents are submitted to PDSD. 2. COMMENT: For Previous Comments 7,9,15, and 16, provide the email correspondence from TDOT that 6th Avenue is at its maximum width and that future R/W will not be required. (While this location is very close to the south edge of the Downtown Insert it is to close to the edge and could be interpreted as outside the insert area.) PREVIOUS COMMENT 7: 2-06.4.8.A - This site is made up of three parcels. Prior to approval of the DP a Pima County Tax Parcel Combo will be required. PREVIOUS COMMENT 9: 2-06.4.9.H.2 - Also, Sixth Avenue is a major street and per the adopted MS&R map, will be widened to 90 feet. Per your plan the ½ R/W is just short of 40 feet in width. The future right of way information shall be drawn, labeled and dimensioned, including the future svt's. PREVIOUSCOMMENT 15: 2-06.4.9.I - If right of way dedication is required revise the drawing with the new right of way line, future curb and sidewalks, labeled and dimensioned. PREVIOUS COMMENT 16: 2-06.4.9.J - If dedication is not required or proposed draw the Major Street right-of-way lines for Sixth Avenue, (Add the MS&R future sidewalk, right-of-way lines, sight visibility triangles, etc.). PREVIOUS COMMENT 17: 2-06.4.9.O - Sixth Avenue is an Arterial roadway listed on the MS&R map. The street building setbacks along the Sixth Avenue frontage should be labeled from the existing and future back of curb locations. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson "Unified Development Code" - Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, Contact David Rivera at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 01/17/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 01/21/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 01/21/2020 | DAVID RIVERA | ZONING HC | REVIEW | Approved | |
| 01/27/2020 | MARTIN BROWN | COT NON-DSD | FIRE | Approved | |
| 01/27/2020 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Approved | |
| 01/28/2020 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE A resubmittal with a Comment Response Letter is required. DESCRIPTION: SITE/GRADING - Mattress Factory, building expansion. PERMIT: DP19-0205 Please include this number on all future correspondence and in Filedrop's "Project Description" field. FEE BALANCE: $0 (zero) VIEW DOCUMENTS and reviewer's comments on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Documents section, click on blue icon to the right of each document - Reviews section, click on Review Details YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff - In the Project Description field, enter the Activity/Permit Number - Name your 3rd submittal documents to start with the number, for example: 3_Plan_Set Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, 2nd Floor Tucson, AZ 85701 email: COTDSDPermits@TucsonAz.gov |
| 12/20/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/28/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |