Permit Number: DP19-0183
Parcel: 105102470

Address:
4405 N 1ST AV

Review Status: Completed

Review Details: REVISION - - 1ST

Permit Number - DP19-0183
Review Name: REVISION - - 1ST
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/13/2020 SBEASLE1 ZONING REVIEW Reqs Change (Review comments from Okay to Submit)

CDRC TRANSMITTAL
TO: Development Services Department
Plans Coordination Office
FROM: Steve Shields, Section Manager
PROJECT: First & Wetmore - 4405 N. First Ave.
Development Package (1st Revision), DP19-0183

TRANSMITTAL DATE: April 13, 2020
DUE DATE: Revision #1 Ok to Submit.

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

1. 2-06.4.9.H.5.a - Sheet 2 of 4 shows the angled accessible parking along the southern border of the site as "EXISTING ADA COMPLIAN PARKING TO REMAIN" but based on the most current aerial photos the existing parking along the southern border is perpendicular to the PAAL. Clarify which is correct.

2. 2-06.4.9.H.5.a - Sheet 1 of 4 under "DEVELOMENT PAACKAGE CALCULATIONS, HANDICAP ACCESSIBLE PARKING: PROVIDED you show two (2) provided but on the plan there are three (3).

3. 2-06.4.9.H.5.a - The angle shown for the angled parking 30 degrees does not appear to be correct. 30 degree parking is closer to parallel parking. What is shown is closer to 90 degree parking. Once the angle of the parking is confirmed other dimension such as space depth may be affected.

4. 2-06.4.9.H.5.a - The Curb Length dimension shown on sheet 2, see UDC Figure 7.4.6-A: Motor Vehicle Use Area Dimensions.

5. 2-06.4.9.H.5.a - Fully dimension the accessible vehicle parking spaces, one must meet the requires for a van accessible space, see ICC A117.1-2009.

6. 2-06.4.9.H.5.a - Show the required accessible signage on the plan and provide a large scale sign detail including a van accessible sign.

7. 2-06.4.9.H.5.a - Show the required stacking spaces on the plan.

8. Provide a detailed response letter with your next submittal. Your revision letter was very vague.

If you have any questions about this transmittal, please contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
05/11/2020 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP19-0183

1) Provide a complete pedestrian circulation path per COT TSM section 7-01.3.3.B, includes a path to the proposed trash enclosures. There is an onsite path to the west of the trash enclosures that appears to be easily extended
2) The previous site plan had wheelstops at the end of the parking stalls to prevent vehicles from extending into a landscape screen. It appears that wheels stops are still needed. Show that with a 2.5' vehicle overhang that the landscape screen is not impacted
3) Show on plans the maximum cross slope and running slope for the new/modified accessible parking spaces. Provide a ADA compliant path from the eastern most proposed space

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
05/12/2020 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change REVISION PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is required

Project Description: SITE/GRADING - First and Wetmore, add drive-thru lane, existing building.

Permit: DP19-0183

Fees Due: $ 181.50
Please pay fees before sending in a resubmittal

Online Payment
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. NOTE: It may take 1-2 days for complete permit information to be available online
2. Visa, MC, Discover or American Express or pay by checking account
3. Not case-sensitive but a hyphen is needed, for example: dp19-2000
4. Enter your Permit Nbr
5. Business/Individual Name: Leave blank
6. Click the blue Continue tab
7. If any issues, try using the browser Internet Explorer

VIEW the review comments and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on blue icon to the right of each document

After the corrections are made, please name your Revision #1, 2nd submittal documents accordingly,
for example: REV-1_2_Plan_Set.

YOUR NEXT STEPS: Submit documents to the Filedrop
https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

CONTACT US Monday-Friday, 8:00 am to 12:00 noon
https://www.tucsonaz.gov/pdsd/virtual-service-counter
For information or an over-the-counter review, sign in to the
Virtual Service Counter and we will give you a call.

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
05/12/2020 SBEASLE1 OUT TO CUSTOMER Completed