Permit Number: DP19-0183
Parcel: 105102470

Address:
4405 N 1ST AV

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP19-0183
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/02/2019 SBEASLE1 START PLANS SUBMITTED Completed
08/07/2019 MARTIN BROWN COT NON-DSD FIRE Approved
08/22/2019 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
PDSD Zoning Review Section

PROJECT: Drive-Through for Existing Food Service Use
Development Package (1st Review) - 4405 N. 1st Avenue
DP19-0183 - C-3 Zoning (No change of use)

TRANSMITTAL DATE: August 22, 2019
DUE DATE: August 30, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is August 1, 2020.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

1. COMMENT: 2-06.4.2.A - Label above the title block of plan sheets "New Drive-Through".


2. COMMENT: 2-06.4.2.A - Provide the development package case number, DP19-0183, adjacent to the title block on each sheet.


3. COMMENT: 2-06.4.4.B - Label the following on the location map; Stone Avenue, Rillito Creek, and Roger Road is labeled in the wrong area of the location map.


4. COMMENT: 2-06.4.4.C - Label the section corners 24, 19, 25, 30 at the Roger Road and First Avenue and at the section corners 13, 18, 24, 19 for the north section on First Avenue.


5. COMMENT: 2-06.4.7.A.8.Include a vehicular use area expansion calculation as it applies to this project.


6. COMMENT: 2-06.4.8.A - Label the distance and bearing for the subject parcel.


7. COMMENT: Label the location of the drive-through window.


If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
08/22/2019 DAVID RIVERA ZONING HC REVIEW Approved
08/28/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
08/28/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP19-0183

1) Show vehicle stacking in the drive thru lane per UDC section 7.4.7. Show that vehicle stacking will not interfere with the pedestrian circulation path

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
08/28/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change The Development Package will contain the following identification in the lower right corner of each sheet:

Any relevant case numbers for reviews or modifications that affect the site.

Provide the development package case number DP19-0183.

Ensure that all Zoning and Engineering comments and concerns are addressed.
08/29/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is required
Permit/Activity Number: DP19-0183
Description: SITE/GRADING - First and Wetmore, add drive-thru lane, existing building
Fees Due: $1,495.80
Please pay the total fees (or Review Fees at a minimum):
1. Online
2. In person at the permit counter (Mon-Fri, 8:00 AM to 2:00 PM)
3. By mail - a check payable to City of Tucson, address is shown below, include the Activity Number
NEW: Online payments are now accepted.
1. Visa, MC, Discover, or American Express
2. No cost to the customer
3. All data and transactions are securely encrypted
4. City staff cannot view your online payments

Link to Online Payments:
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. Not case-sensitive but a hyphen is needed, e.g.: dp19-0000
2. Simply enter your Permit Nbr. and click the “Continue” tab
3. If any issues, try using the browser Internet Explorer.

To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number.
(If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.)
Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (listing your response to reviewer's comments)
2) Plan Set (all pages, full set)
3) Any other items requested by review staff
Name your 2nd submittal documents accordingly, for example: 2_Plan_Set.
Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
08/29/2019 SBEASLE1 OUT TO CUSTOMER Completed