Permit Number: DP19-0179
Parcel: 12902091E

Address:
181 S TUCSON BL

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0179
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/15/2020 IMONSHI1 ZONING HC REVIEW Reqs Change
01/15/2020 IMONSHI1 ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Iman Monshizadeh
PDSD Zoning Review Section

PROJECT: BROADMOOR ADAPTIVE REUSE
Development Package (3rd Review) 181 S TUCSON BL
DP19-0179 - C-1 Zoning

TRANSMITTAL DATE: January 15th, 2019
DUE DATE: January 17th, 2019

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is July 29, 2020.

*** Address the Zoning follow up comments. Some of the follow up comments have multiple parts. The previous comments have been left as reference for the reviewers and applicant

1. PREVIOUS COMMENT: Previous comment not addressed: Label the following under the location map: "NE ΒΌ of SECTION 17, T. 14 S., R. 14 E.,
G. & S.R.M., CITY OF TUCSON, PIMA COUNTY, ARIZONA"

2. PREVIOUS COMMENT: Previous comment not fully addressed 7: 2-06.4.4.C - Provide section, township and range listed below the location map.

3. NEW COMMENT: The square footage of the building shown on the first sheet does not match that shown on the second and third sheet; provide a constant square footage for the existing 2 story building.

4.PREVIOUS COMMENT: There does not appear to be 51 parking spaces on the parcel. Clarify where the additional parking spaces are located and if offsite provide a parking calculation for the uses the parking is being used or proposed. A recorded parking lease agreement will be required prior to approval of the DP.

5. FOLLOW UP COMMENT: We have received a letter from the law office of Neff & Boyer, P.C stating that the adjacent owners to the east of this development will not grant the developers of this project use of their parking spaces. The provided easement agreement seems to state that Broadmoor has a need for the "occasional" use of 20 parking spaces, it is not clear if these can be used as permanent parking spaces. Zoning cannot approve this site until this issue has been resolved or the correct number of parking spaces is provided. A reduction of parking spaces is possible through a separate IPP application. If you would like a copy of the said letter contact at Iman.Monshizadeh@tucsonaz.gov and a copy will be provided.

If you have any questions about this transmittal, Contact Iman Monshizadeh at (520) 837-4082 or by email at Iman.Monshizadeh@tucsonaz.gov contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
01/15/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
A resubmittal with a Comment Response Letter is required.

Description: SITE - Broadmoor Adaptive Reuse, remove bldg columnar structures.

Permit/Activity Number: DP19-0179
Please include this number on all future correspondence.

Fee Balance: $0 (zero)
View documents and reviewer's comments on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on Review Details

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
- In the Project Description field, enter the Activity Number
- Name your 4th submittal documents accordingly, for example: 4_Plan_Set
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 2nd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov
12/18/2019 SBEASLE1 START PLANS SUBMITTED Completed

Final Status

Task End Date Reviewer's Name Type of Review Description
01/15/2020 SBEASLE1 OUT TO CUSTOMER Completed