Permit Number: DP19-0117
Parcel: 12701008A

Review Status: Completed

Review Details: DEV PKG - REVISION

Permit Number - DP19-0117
Review Name: DEV PKG - REVISION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/09/2019 SBEASLE1 START PLANS SUBMITTED Completed
09/09/2019 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL
TO: Development Services Department
Plans Coordination Office FROM: David Rivera, PDSD Zoning Review Section
PROJECT: At Home - Retail Use Group / General Merchandise Sales
Development Package (2nd Review) - 5255 E. Broadway Boulevard, DP19-0117 - C-1 Zoning (Revision 1)

TRANSMITTAL DATE: September 9, 2019
DUE DATE: October 7, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is May 7, 2020.
***Previous comments are still applicable: please revise the plan and resubmit for review as per our telephone conversation and email correspondence.

1. COMMENT: Zoning has reviewed the revisions listed in the revision letter and the proposed changes to the plans. Address the following comments and resubmit for review. (The zoning comments are minor and zoning is willing to do an over the counter digital review once the corrections have been made on the plans.)

2. COMMENT: 2-06.4.9.H.5.d and 2-06.4.9.R - Include a fully dimensioned detail drawing of the relocated bicycle parking location. The bicycle parking area must meet the minimum width and access requirements as well as provide a minimum width of four feet clear for pedestrian access.

Demonstrate that short term bicycle parking facilities are within 50 feet of the main public entrance.

3. COMMENT: The accessible parking sign must be revised to show a clear dimension from the top of pavement to the bottom of the lower sign (Van Accessible Sign) on the pole.

4. COMMENT: Draw and Label the Main public entrance.

If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Corrected DP Plans
09/10/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change REVISION PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is requested

Permit/Activity Number: DP19-0117
Description: SITE - At Home, new truck well, relocate accessible parking spaces.
The fee balance is $0 (zero).
To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number.
(If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.)
Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (listing your response to reviewer's comments)
2) Plan Set (or sheets)
3) Any other items requested by review staff

After the corrections are made, please name your Revision #1, 3rd submittal documents accordingly,
for example: REV-1_3_Plan_Set.
Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701